Specifications

P a g e | 22
SAM1-3GM and SAM1 MADI Combined User Handbook Version One Issue 1
2.10.5 MADI Bypass
SAM1 MADI features a relay which is wired across the Coax Input and the Coax Loop output
connectors. In default, this relay is switched out of circuit and the Coax Input fed to the MADI
receiver circuitry whist the reclocked output is fed to both Coax outputs simultaneously. If SAM1
MADI is wired in series with other devices using the loop connection then the MADI Bypass relay
can be activated via the setup menu to divert MADI away from the SAM1. The relay will also switch
to bypass mode in the event that SAM1 power should fail thus maintaining MADI connectivity to
any serially connected downstream MADI devices.
2.11 MADI Status SAM1 MADI Only
The MADI Status button is used to access a secondary menu that provides visual feedback of
connected MADI and reference signals.
Coax Present Shows presence and channel counts of a connected coax source
Optical Present Shows presence and channel counts of a connected optical source
Ext Word Clock Ref Displays the presence of a connected Wordclock reference source
Coax Madi Bypass Highlights if the coax bypass relay is active
Selected WC Locked Describes whether the selected reference is locked or not