  R Remote Version 3 User’s Guide    16 
Main Area 
This area shows the state of the selected R series unit and allows basic parameter editing. The display 
depends on the model. 
For Rio3224-D / Rio1608-D / Ri8-D 
The screen is explained here using the Rio3224-D as an example. The number of items in the HA 
display area differs depending on the model. 
The Edit window
 opens if you double-click or right-click and choose [Open Edit Window] anywhere 
other than on a controller.   
①  HA display area 
Here you can view and edit HA settings for the Rio3224-D / Rio1608-D / Ri8-D unit.   
If you press the left mouse button on an area that shows the device's jack number, the indicator of 
the actual device's corresponding jack will light. 
ⓐ  [+48V] button 
Turns phantom power on/off for each channel.   
ⓑ  GAIN knob 
Specifies the analog gain for the HA of the device. The current setting is shown in the 
numeric box located below the knob. 