manual

I/O devices and external head amps
V5 Reference Manual
181
EXTERNAL HA window
Remotely control the external head amp. Display this window by pressing the virtual rack in
the I/O DEVICE screen (EXTERNAL HA page).
1 +48V MASTER
If an external HA is connected, the master phantom power on/off status is shown here.
(The on/off setting is made on the external HA unit itself.)
2 +48V button
These switch phantom power on/off for each channel.
3 GAIN knob
These indicate the gain of the external HA. If you press and select the GAIN knob, you
can make adjustments to gain using the [TOUCH AND TURN] knob. The level meter
located at the immediate right of the knob indicates the input level for the
corresponding port.
4 FREQUENCY knob/HPF button
These controllers switch on or off the high-pass filter built into the external HA, and
adjust its cutoff frequency. If you press and select the FREQUENCY knob, you can make
adjustments using the [TOUCH AND TURN] knob.
5 Rack select tabs
These tabs switch the rack that is displayed in the EXTERNAL HA window.
NOTE
If you connect an additional AD8HR, the setting for this AD8HR will be used.
These knobs and buttons are displayed in the EXTERNAL HA window even if an AD8HR is not
connected, allowing you to create and store a scene even while the AD8HR is not connected.
Error messages related to the SB168-ES will not be displayed. In addition, you will be unable to
set the EtherSound parameters. Use AVS-ESMonitor for these functions.
Remotely controlling an external HA from the input channels on a QL
series console
You will be able to use the external HA in the same way as the head amp on an I/O device or
on the QL console. For details on the GAIN/PATCH window, refer to “Making HA (Head Amp)
settings” on page 28.
Controlling an internal head amp
Control the internal head amps (“internal HA”) in QL series consoles. It is not necessary to
change the input patch.
2
3
5
1
4
STEP
1. Use the Bank Select keys and the [SEL] key to access the SELECTED CHANNEL VIEW
screen that includes the channel for the head amp that you want to control.
2. Press the GAIN/PATCH field of the channel whose external HA you want to adjust.
3. Press the PATCH button in the GAIN/PATCH window, and select the input port
assigned to the external HA.
4. Remotely control the external head amp in the GAIN/PATCH window.
STEP
1. Press the INTERNAL HA tab in the upper part of the I/O DEVICE window.
2. Set the output port on the INTERNAL HA window, as necessary.
SELECTED
CHANNEL VIEW
screen
GAIN/PATCH window