User Manual

Table Of Contents
ProVisionaire Design DME7 Component Guide
42
a Comp260 [ON] button
Switches between enabling or disabling the Comp260 function.
b Compressor curve
This shows the effect as a graph. The horizontal axis is the input signal level, and the
vertical axis is the output signal level.
c [GR] meter
Indicates the amount of gain reduction.
d [KEY IN] list box
From this list, select the input signal that is used as the key-in signal; that is, the reference
signal that causes the compressor to operate.
The following choices are provided.
[Self]
For a monaural channel component, the input signal is used as the trigger source.
[L]
For a stereo channel component, the L input signal is used as the trigger source.
[R]
For a stereo channel component, the R input signal is used as the trigger source.
[KeyIn]
The key-in input is used as the trigger source.
[Max In]
This sets the signal with the largest value in a stereo channel or a multi-channel
component as the trigger source.
1–64
This sets the specified channel signal in a multi-channel component as the trigger
source.
e [THRESHOLD] knob
Specifies the threshold level at which the Comp260 will take effect.