User Manual

Table Of Contents
ProVisionaire Design DME7 Component Guide
27
d Room selection dropdown list
This selects the room to which the combine buttons shown below are assigned.
e
Combine buttons
These specify which rooms are combined. Non-adjacent rooms can also be combined.
Combiner parameter setting window (Room Combiner)
Here you can view and edit the parameters of all rooms.
When rooms are connected, [ROOM IN] can be adjusted for each room; however, the setting
of the lowest-numbered room takes priority for [PAGING]/[BGM]/[ROOM OUT].
a Index
Shows the number and color assigned to the room. Connected rooms are shown in the
same color.
b [NAME] box
Indicates the room name. You can double-click the name and edit it.
c
[ROOM IN]
Adjusts the send amount from ROOM IN to ROOM OUT, and turns mute on/off.
d
[PAGING]
Adjusts the send amount from PAGING to Room OUT, and turns mute on/off.
e
[BGM]
Selects one of BGM1 to 4, adjusts the amount of that BGM that is sent to ROOM OUT, and
turns mute on/off.