User Manual

Table Of Contents
ProVisionaire Design DME7 Component Guide
16
a
ANC [ON] button
Switches the ANC function between enabled and disabled.
b AMIBIENT
Level meter
Shows the level of ambient noise.
[THRESHOLD] knob
Specifies the average level of ambient noise. If the level of ambient noise exceeds this
value, the level of the program source is raised; if the level is lower than this value, the
level of the program source is lowered.
c GAP
[THRESHOLD] knob
Specifies the threshold value of the program source.
If the level of the program source remains below the threshold for a specified time, it
will be interpreted as a gap.
[TIME] knob
Specifies the time required for a gap to be detected.
d PROGRAM SOURCE GAIN
[MIN GAIN] knob
Specifies the minimum value of program source level compensation.
[MAX GAIN] knob
Specifies the maximum value of program source level compensation.
[GAIN RATIO] knob
Specifies the ratio of program source level compensation. This is specified as the ratio
Program source compensation amount: Amount of ambient noise increase from
the threshold value.
[RESPONSE TIME] knob
Specifies the response speed for level compensation.
Level meter
Indicates the output level of the program source after compensation.
Control
Parameter types of the input/output values for each Port
Input Value
Control Parameter Output Value
Type Range
Input Port Name Parameter Range
Output Port Name Type Range
Value Num 0,1
On OFF:0, ON:1
On Value Num 0,1