User Manual

Table Of Contents
ProVisionaire Design DME7 Component Guide
156
Suspend
This is a control component to temporarily stop the output of the input signal.
(For 2 inputs)
INPUT
1: Channel 1 input value
2: Channel 2 input value
On1: Input value to control the channel 1 button (OFF:0, ON:1) (*)
On2: Input value to control the channel 2 button (OFF:0, ON:1) (*)
OUTPUT
1: Channel 1 input value
2: Channel 2 input value
On 1: Output value when the channel 1 button is switched (OFF:0, ON:1) (*)
On 2: Output value when the channel 2 button is switched (OFF:0, ON:1) (*)
* is displayed when the Parameters Control PINs are checked.
Suspendcomponent editor
When this is ON, the signal output is stopped. P a
Parameter types of the input/output values for each Port
Input Value Operation Output Value
Type Range Input Port Name
Trigger/
Processing
Output Port Name Type Range
Through
CH (1,2..)
Processing :
Suspend
CH (1,2..) Same value as the Input Value
Value Num OFF:0, ON:1
On (1,2..)
On (1,2..) Value Num OFF:0, ON:1