amp with 26 dB voltage gain. As necessary, make appropriate adjustments
to the DME7’s LIMITER settings and output level, and to the power amp’s
voltage gain and attenuator. For example if using a power amp whose
voltage gain is 30 dB, you should either lower the power amp’s attenuator
value by 4 dB or lower the DME7’s LIMITER Threshold value by 4 dB.
b [STORE] button
Saves the current state as a library item (file extension [.spld]).
[SP] tab
a [PHASE] graph
Displays a crossover phase response curve. This display takes into account the response
of the PEQ and the Delay. Output channels are color-coded.
b [LEVEL] graph
Displays a crossover amplitude response curve. This display takes into account the
response of the PEQ and the Output Level. Output channels are color-coded.
c [INPUT] meter
Shows the input signal level.
d [INPUT LEVEL] knob
Specifies the input level. You can double-click the numeric display area and directly enter
a numeric value.
e [Band Select] buttons
If a button is selected, the current value is shown in "EQ," below. For bands whose
[BYPASS] button is on, the indicator below that [Band Select] button is lit.
f [FLAT ] button
Sets the "EQ" [GAIN] to 0 dB.
g GRAPH VISIBLE buttons
These buttons switch the graph of the corresponding output channel between visible and