User manual

MENU DESCRIPTION
GPOutput1 is ON when setup 1 has been recalled.
GPOutput2 is ON when setup 2 has been recalled.
GPOutput3 is ON when setup 3 has been recalled.
GPOutput4 is ON when setup 4 has been recalled.
GPOutput5 reflects the GPInput1 (with a small delay and without glitches).
GPOutput6 reflects the GPInput2 (with a small delay and without glitches).
GPOutput7 reflects the GPInput3 (with a small delay and without glitches).
GPOutput8 reflects the GPInput4 (with a small delay and without glitches).
Warning: If a setting is changed on the NXAMP unit (through front panel or remote
control), the LED will not turn off, and if the corresponding button is pressed again, the
originally saved setup will be recalled.
GPIO mode 5 (Loudspeaker Impedance monitoring)
This mode is used for outputting the status of the loudspeaker impedance monitoring
system integrated into the NXAMP on the GPIO port. You will need to set up the Load
Monitoring in the Options => Load Monitor menu to use this function properly.
Pin Name In/Out
Meaning when set to 0
(Default)
Meaning when set to 1
GPInput 1 In CH 1 unmuted CH 1 muted
GPInput 2 In CH 2 unmuted CH 2 muted
GPInput 3 In CH 3 unmuted CH 3 muted
GPInput 4 In CH 4 unmuted CH 4 muted
GPInput 5 In NXAMP is ON NXAMP is in Stand-by
GPOutput 1 Out CH 1 is not ok CH 1 Impedance is OK
GPOutput 2 Out CH 2 is not ok CH 2 Impedance is OK
GPOutput 3 Out CH 3 is not ok CH 3 Impedance is OK
GPOutput 4 Out CH 4 is not ok CH 4 Impedance is OK
GPOutput 5 Out Not All channels are ok All Impedance are OK
GPOutput 6 Out Not all amplifiers are ok All amplifiers are OK
GPOutput 7 Out Unused Unused
GPOutput 8 Out Unused Unused
PAGE 68 OF 140