User's Manual
“Remote Control” dialog box Chapter 7. Dialog boxes
MTX Editor User’s Manual
163
❑ “Remote Control” dialog box
Here you can check the port numbers for connecting an external controller, or make settings for
connecting an external controller to RS-232C.
• A total of nine external controllers and wireless DCP units can be connected to a single
MTX.
• The IP address of the MTX can be viewed in the “Device Information” dialog box.
● [Device:] box
Select the MTX unit for which you want to make settings. The UNIT ID, device type,
and device name are shown.
● [Network IP PORT No.]
This shows the port number of the MTX3’s NETWORK connector or the MTX5-D’s
Dante [PRIMARY]/[SECONDARY] connectors. You can connect up to eight external
controllers or wireless DCP to the port.
● [Remote(RS-232C) BIT RATE] box
Selects the RS-232C communication speed. You can select “38400” bps or
“115200” bps. You can connect one external controller to the RS-232C.
● [OK] button
Saves the settings and closes the dialog box.
● [Cancel] button
Closes the dialog box without saving the changes.