User's Manual
“Preset Link” dialog box Chapter 6. Presets
MTX Editor User’s Manual
126
● [Emergency Recall]
This specifies the preset that will be recalled when the MTX receives an EMG
(Emergency) signal from an external device or when the input to the +24V [GPI IN]
pin (IN 8 for the MTX3; IN 16 for the MTX5-D) falls below 2.5V.
• [OFF]/[ON] toggle button
Switches recall on/off. Turn this off if +24V is not being applied to the +24V [GPI
IN] pin.
• Preset box
Selects the preset number that will be recalled.
● [Close] button
Closes the “Preset” dialog box.
“Preset Link” dialog box
Here you can make settings for linking preset recall between MTX systems.
• Preset list
This lists the preset names for each MTX system in the project. Select the check
boxes of presets for which you want preset recall to be linked.
• [All ON] button
Selects the check boxes of all presets.
• [All OFF] button
Clears the check boxes of all presets.
• [OK] button
Specifies the preset recall link settings and closes the dialog box.
•[Cancel] button
Cancels the preset recall link settings and closes the dialog box.