Step 6 Remote Head Amp Control
31
■Setting up MY16-ES64 (M7CL) (controlling device)
Select MY16-ES64 (M7CL) in Tree view or List view and select the control tab.
Serial Port Mode
The Serial Port Mode will depend on the host device of the MY16-ES64. This example uses
M7CL. Since M7CL uses its REMOTE port to output control data, select Mode 3. See the next
side notes.