User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Remount function to USB flash drives
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- Table of Contents
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Channel Job
V5.8 Reference Manual
70
Selecting the channels that will belong to a specific mute group
NOTE
• You may assign a single channel to more than one mute group.
• The DCA/MUTE GROUP field of the OVERVIEW screen indicates the mute group(s) to which
each channel is assigned. Numbers that are lit red in the lower line of this field indicate the mute
groups to which that channel belongs.
• If the dimmer level is set to any level other than -∞ dB, these numbers will light orange.
For a channel for which the Mute Safe function (page 72) has been turned on, an “S” indicator
will light up green at the right end of the bottom row.
DCA/MUTE GROUP ASSIGN MODE window
Here you can select the channels that will be assigned to each mute group.
1 CLEAR ALL button
Clears all channels that are assigned to the currently-selected mute group.
2 DCA GROUP ASSIGN/MUTE GROUP ASSIGN buttons
Toggle between the DCA GROUP ASSIGN window and MUTE GROUP ASSIGN window.
3 Mute group assign field
This area displays the channels assigned to the currently-selected mute group.
While this window is displayed, press the [SEL] key for the channel that you want to
assign to the mute group. The channel will be assigned to the mute group, and the
on-screen fader for that channel will turn red. Press the same [SEL] key once again if you
want to remove the channel from the group.
If the MUTE SAFE button is on, this field displays the channels that enabled for mute safe
(that is, excluded from the mute groups). The operation procedure to apply or cancel
mute safe to the channels is the same as that for assigning or removing channels to or
from a mute group. The on-screen faders of the assigned channels will turn green.
4 NAME EDIT button
Edits the group name of the currently-selected mute group.
When you press this button the keyboard window will appear, allowing you to enter or
edit the text.
STEP
1. In the Function Access Area, press the CH JOB button.
2. Press the MUTE GROUP button in the CH JOB menu.
3. Use the mute group control buttons in the DCA/MUTE GROUP ASSIGN MODE
window to select the mute group to which you want to assign channels.
4. Press the [SEL] key for the input channels/output channels that you want to operate
(multiple selections are allowed).
Function
Access Area
CH JOB
menu
3
4
5
8
7
1
2
6
9