User Manual
Table Of Contents
- How to Use This Reference Manual
- Contents
- Function Tree
- SELECTED CHANNEL section
- Channel Strip section
- Input and output patching
- Input channels
- Signal flow for input channels
- Specifying the channel name, icon, and channel color
- Making HA (Head Amp) settings
- Sending the signal from an input channel to the STEREO/MONO bus
- Added pan function (Monaural input channels only)
- Sending a signal from an input channel to a MIX/ MATRIX bus
- Channel name display indication
- Correcting delay between channels (Input Delay)
- Surround output for input channels
- Channel library operations
- OUTPUT channels
- Signal flow for output channels
- Specifying the channel name, icon, and channel color
- Sending signals from MIX channels to the STEREO/ MONO bus
- Sending signals from MIX channels and STEREO/ MONO channels to MATRIX buses
- Correcting delay between channels (Output Delay)
- Using the PORT TO PORT function
- Channel library operations
- EQ and Dynamics
- Channel Job
- Scene memory
- Monitor and Cue functions
- Talkback and Oscillator
- Meters
- Graphic EQ, Parametric EQ, effects, and Premium Rack
- I/O devices and external head amps
- MIDI
- Recorder
- AFC IMAGE Control
- Setup
- About the SETUP screen
- User settings
- Preferences
- USER DEFINED keys
- Functions that can be assigned to USER DEFINED keys
- USER DEFINED knobs
- Functions that can be assigned to USER DEFINED knobs
- Custom fader bank
- Console Lock
- Saving and loading setup data to and from a USB flash drive
- Remount function to USB flash drives
- Word clock and slot settings
- Using cascade connections
- Basic settings for MIX buses and MATRIX buses
- Switching the entire phantom power supply on/ off
- Specifying the brightness of the touch screen, LEDs, channel name displays, and lamps
- Setting the date and time of the internal clock
- Setting the network address
- Setting up the Dante audio network
- Dante Device Lock
- Support for Dante Domain Manager
- Using GPI (General Purpose Interface)
- Help function
- Other functions
- Initializing the unit to factory default settings
- Adjusting the detection point of the touch screen (Calibration function)
- Adjusting the faders (Calibration function)
- Fine-tuning the input and output gain (Calibration function)
- Adjusting the LED color (Calibration function)
- Adjusting the brightness of the channel name display
- Adjusting the contrast of the channel name display
- Initializing the Dante audio network settings
- Update procedure for NAME SUB CPU firmware
- Update function to Dante firmware
- Warning/Error Messages
- Index
- Data List
- Table of Contents
- EQ Library List
- DYNAMICS Library List
- Dynamics Parameters
- Effect Type List
- Effects Parameters
- Premium Rack Processor Parameters
- Parameters That Can Be Assigned to Control Changes
- NRPN Parameter Assignments
- Mixing Parameter Operation Applicability
- MIDI Data Format
- Input/Output Characteristics
- Electrical Characteristics
- Mixer Basic Parameters
- Pin Assignment
- MIDI Implementation Chart
Data List
20
M.BAND COMP
Two input, two output 3-band compressor, with individual solo and gain reduction metering for
each band.
Premium Rack Processor Parameters
Portico5033
This models an analog 5-band EQ made by the RND company.
Portico5043
This models an analog compressor/limiter made by the RND company.
LIM.ATK 0–120 ms Attack time of the limiter
LIM.REL
*1
Release time of the limiter
LIM.KNEE 0–5 Knee of the limiter
LIM.BYP OFF/ON Bypasses the limiter
PRESENCE –10 to +10
Positive (+) values lower the threshold of the high band and raise the
threshold of the low band. Negative (–) values do the opposite. If this is
set to 0, the high, mid, and low bands will be affected in the same way.
LOOKUP 0.0–100.0 ms Lookup delay
MAKE UP OFF/ON Automatically adjusts the output level
*1. 6.0 ms–46.0 s (fs=44.1 kHz), 5.0 ms–42.3 s (fs=48 kHz)
Parameter Range Description
L-M XOVER 21.2 Hz–8.00 kHz Crossover frequency between the low and mid bands
M-H XOVER 21.2 Hz–8.00 kHz Crossover frequency between the mid and high bands
SLOPE –6 dB, –12 dB Filter slope
LOW GAIN –12.0 dB to +12.0 dB Low band gain
MID GAIN –12.0 dB to +12.0 dB Mid band gain
HI. GAIN –12.0 dB to +12.0 dB High band gain
TOTAL –72.0 dB to +12.0 dB Overall gain
CEILING –6.0 dB to 0.0 dB, OFF Restricts the output so that it will not exceed the specified level
LOW THRE –54.0 dB to 0.0 dB Threshold of the low band compressor
LOW RAT 1:1 to 20:1 Ratio of the low band compressor
LOW ATK 0–120 ms Attack time of the low band compressor
LOW REL
*1
*1. 6.0 ms–46.0 s (fs=44.1 kHz), 5.0 ms–42.3 s (fs=48 kHz)
Release time of the low band compressor
LOW KNEE 0–5 Knee of the low band compressor
LOW BYP OFF/ON Bypasses the low band compressor
MID THRE –54.0 dB to 0.0 dB Threshold of the mid band compressor
MID RAT 1:1 to 20:1 Ratio of the mid band compressor
MID ATK 0–120 ms Attack time of the mid band compressor
MID REL
*1
Release time of the mid band compressor
MID KNEE 0–5 Knee of the mid band compressor
MID BYP OFF/ON Bypasses the mid band compressor
HI. THRE –54.0 dB to 0.0 dB Threshold of the high band compressor
HI. RAT 1:1 to 20:1 Ratio of the high band compressor
HI. ATK 0–120 ms Attack time of the high band compressor
HI. RAT
*1
Release time of the high band compressor
HI. KNEE 0–5 Knee of the high band compressor
HI. BYP OFF/ON Bypasses the high band compressor
LOOKUP 0.0–100.0 ms Lookup delay
MAKE UP OFF/ON Automatically adjusts the output level
Parameter Range Description
Parameter Range Description
ALL BYPASS OFF, ON
Turns bypass on/off for the EQ. Even in the bypassed state, the signal will
pass through the input/output transformers and the amp circuit.
TRIM –12.0 to 12.0 dB Input gain
LF FREQ 30.00 to 300.0 Hz Center frequency of the LF band
LF GAIN –12.0 to 12.0 dB Gain of the LF band
LMF IN OFF, ON Switches the LMF band on/off
LMF Q 0.70 to 5.00 Q of the LMF band
LMF FREQ 50.00 to 400.0 Hz Center frequency of the LMF band
LMF GAIN –12.0 to 12.0 dB Gain of the LMF band
MF IN OFF, ON Switches the MF band on/off
MF Q 0.70 to 5.00 Q of the MF band
MF FREQ 330.0 to 2500 Hz Center frequency of the MF band
MF GAIN –12.0 to 12.0 dB Gain of the MF band
HMF IN OFF, ON Switches the HMF band on/off
HMF Q 0.70 to 5.00 Q of the HMF band
HMF FREQ 1.80k to 16.0k Hz Center frequency of the HMF band
HMF GAIN –12.0 to 12.0 dB Gain of the HMF band
LF/HF IN OFF, ON Switches the LF/HF bands on/off
HF FREQ 2.50k to 25.0k Hz Center frequency of the HF band
HF GAIN –12.0 to 12.0 dB Gain of the HF band
Parameter Range Description
IN OFF, ON
Turns bypass on/off for the compressor. When bypassed, the button will
be unlit. However even in the bypassed state, the signal will pass through
the input/output transformers and the amp circuit.
FB OFF, ON Switches between feed-forward type and feed-back type
THRESHOLD –50.0 to 0.0 dB Threshold level
RATIO 1.10 : 1 to 28.9 : 1, LIMIT Compression ratio
ATTACK 20 to 75 ms Attack time
RELEASE 100 ms to 2.50 sec Release time
GAIN –6.0 to 20.0 dB Output level