User Manual

Table Of Contents
I/O devices and external head amps
V5.8 Reference Manual
172
6 Displayed port switch tabs
These tabs switch the port that is displayed in the I/O DEVICE HA window.
7 GC ALL ON button/GC ALL OFF button
Switch Gain Compensation on or off for all input channels simultaneously.
8 GC indicator
Indicates the fixed gain value output to the audio network if the Gain Compensation
function is turned on.
Remotely controlling from the input channels
To remotely control the I/O device’s head amp from an input channel of the QL series console,
operate the GAIN/PATCH window for the channel for which you want to control.
Remote control settings
• MTX/MRX series
The following settings are necessary to control the MTX/MRX series remotely..
• Stagetec NEXUS(XDIP)
Network configuration is required to control NEXUS(XDIP) remote. For details, please contact
the Stagetec Company, or refer to the website of the Stagetec Company.
Also, in order to validate the remote control setting contents from the QL series, NEXUS must
be used to properly set the internal routing of XDIP.
Remotely controlling an amp
This section explains how to remotely control an amp unit that’s connected to the Dante connector.
I/O DEVICE screen (AMP page)
1 Display switch buttons
Press one of these buttons to view the corresponding I/O device.
For more information about VIRTUAL/CONFLICT/DUPLICATE displayed below this
button, refer to
1 on page 163, “I/O device list.”
2 ID/Model name display
This shows the ID number, model name, and version of the I/O device.
3 DANTE SETUP button
Press this button to open the DANTE SETUP window, in which you can make settings
for the audio network.
STEP
1. Install the MTX-MRX Editor on the computer.
2. Connect the MTX-MRX series and Editor according to the MTX-MRX Editor user
guide.
3. Set remote (RS-232C) BET RATE: 38400 in Chapter 7 Remote Control dialog of the
MTX-MRX Editor User Guide.
4. Match the subnet of the QL series on the NETWORK screen (FOR DEVICE CONTROL
page) with the subnet of MTX-MRX series.
5. Place the ANALOG IN component using the MRX Designer, since the MRX Series
components can be freely placed therein.
STEP
1. Press the AMP tab in the upper part of the I/O DEVICE screen.
2. Press the I/O device displayed on the I/O DEVICE screen (AMP page).
3. Set the output port on the OUTPUT PATCH window, as necessary.
Refer to step 7 in “I/O device patching” on page 163.
1 2
3