User's Manual

GEO M6 HARDWARE SETUP PROCEDURE Page 27/62
1 to 3 (maximum) GEO M6 wall mounted 8.3.1
Required items
- 1 x VNI-WS15
- 1 x GMT-LBUMP
- 1 to 3 GMT-BNFIX
- 3 x 12mm diameter screws (not provided)
IMPORTANT
Ensure that the wall is strong enough to hold GEO M6 cluster weight and that the 12
mm diameter screws and corresponding plugs required to fix the VNI-WS15 on the wall
are properly dimensioned.
Procedure
- 3 x 12mm diameter screws (not provided) are required to fix the VNI-WS15 support to the wall;
- Connect GMT-LBUMP to top cabinet by inserting the GMT-BNFIX axis through front holes and
secure axis and rear link with GMT-BNFIX screws;
- Connect subsequent cabinets with appropriate inter-angle values;
- Connect the VNI-WS15 suspension plate to the GMT-LBUMP by using the M6x20 screws provided
with the GMT-LBUMP
NB: please do not use the screws supplied with VNI-WS15, too long for this application case
- Position the 6x20 screws in the oblong hole so that required vertical angle is obtained
- Secure the screws with Loctite 243 or equivalent
- Suspend to the wall suspension using the shoulder screws supplied with VNI-WS15
- Secure the assembly with the VNI-WS15 safety cable
- Adjust horizontal angle