User Manual
43
1. NOTE ON/OFF
STATUS: 9nH/8nH
2. PROGRAM CHANGE
STATUS: CnH
3. PITCH BEND CHANGE
STATUS: EnH
4. CONTROL CHANGE
STATUS: BnH
<BANK SELECT MSB/LSB> 00H/20H
Cntrl# parameter Data Range
0 Bank Select MSB 63 (0x3F): Exclusive to EX
32 Bank Select LSB 0 (0x00):Preset1 Voice
1 (0x01):Preset2 Voice
2 (0x02):Internal1 Voice
3 (0x03):Internal2 Voice
64 (0x40):Performance
0 Bank Select MSB 0 (0x00): GM
32 Bank Select LSB 0 (0x00):Internal1 Voice
0 Bank Select MSB 127(0x7F): GM
32 Bank Select LSB 0 (0x00):Internal2 Voice
New bank selection will not become effective until the Program Change message is received.
<MODULATION> 01H
Cntrl# parameter Data Range
1 Modulation 0...127
<BREATH CONTROLLER> 02H
Cntrl# parameter Data Range
2 Breath Controller 0...127
<FOOT CONTROLLER> 04H
Cntrl# parameter Data Range
4 Foot Controller 0...127
<PORTAMENTO TIME> 05H
Cntrl# parameter Data Range
5 Portamento Time 0...127
Setting the value to 127 produces maximum portamento time and 0 results in minimum portamento
time.
<DATA ENTRY MSB/LSB> 06H/26H
Cntrl# parameter Data Range
6 Data Entry MSB 0...127
38 Data Entry LSB 0...127
Messages which set the value for the parameter specified by RPN.
<MAIN VOLUME> 07H
Cntrl# parameter Data Range
7 Main Volume 0...127
<PAN POT> 0AH
Cntrl# parameter Data Range
10 Panpot 0...127
Setting the value to 127 positions to the right most and 0 positions to the left most.
<EXPRESSION> 0BH
Cntrl# parameter Data Range
11 Expression 0...127
<CONTROL CHANGE 13> 0DH
Cntrl# parameter Data Range
13 Control Change 13 0...127
<SUSTAIN> 40H
Cntrl# parameter Data Range
64 Sustain 0...127 (0-63:Off, 64-127:On)
<PORTAMENTO> 41H
Cntrl# parameter Data Range
65 Portamento 0...127 (0-63:Off, 64-127:On)
Portamento is applied according to the amount set in the Portamento Time when the Prtament is
set to ON. MONO is selected when the Prtament is set to ON: Single Trigger mode is selected. In
the other cases: Multi Trigger mode.
<SOSTENUTO> 42H
Cntrl# parameter Data Range
66 Sostenuto 0...127 (0-63:Off, 64-127:On)
<HARMONIC CONTENT> 47H
Cntrl# parameter Data Range
71 Harmonic Content 0...127 (0:-64, 64:+0, 127:+63)
Adjusts the resonance. Effective range may be narrower than the available range.
<RELEASE TIME> 48H
Cntrl# parameter Data Range
72 Release Time 0...127 (0:-64, 64:+0, 127:+63)
Adjusts the envelope release time. Effective range may be narrower than the available range.
<ATTACK TIME> 49H
Cntrl# parameter Data Range
73 Attack Time 0...127 (0:-64, 64:+0, 127:+63)
Adjusts the envelope attack time. Effective range may be narrower than the available range.
<BRIGHTNESS> 4AH
Cntrl# parameter Data Range
74 Brightness 0...127 (0:-64, 64:+0, 127:+63)
Default:40H
Adjusts the filter cut-off frequency. Effective range may be narrower than the available range.
<PORTAMENT CONTROL> 54H
Cntrl# parameter Data Range
84 Portamento control 0...127
<EFFECT SEND LEVEL 1 (REVERB)> 5BH
Cntrl# parameter Data Range
91 Effect 1 Depth 0...127
Adjusts the reverb send level.
<EFFECT SEND LEVEL 3 (CHORUS)> 5DH
Cntrl# parameter Data Range
93 Effect3 Depth 0...127
Adjusts the chorus send level.
<DATA INCREMENT/DECREMENT> 60H/61H
Cntrl# parameter Data Range
96 Increment 0...127
97 Decrement 0...127
The data byte is ignored.
Messages which increase or decrease the MSB value designated by RPN.
<REGISTERED PARAMETER NUMBER (RPN) LSB/MSB> 64H/65H
Cntrl# parameter Data Range
100 RPN LSB 0...127
101 RPN MSB 0...127
The following parameters can be designated.
RPN
LSB MSB MSB parameter Data Range
00H 00H mmH Pitch Bend Sensitivity mm:00H-18H(0-+24)
Default:02H
01H 00H mmH Fine Tune mm:00H-40H-7FH(-64-0-+63)
Default : 40H 00H
02H 00H mmH Coarse Tune mm:28H-40H-58H(-24-0-+24)
Default : 40H 00H
7FH 7FH --- Null ---
5. CHANNEL MODE MESSAGES
<ALL SOUNDS OFF > 78H
Cntrl# parameter Data Range
120 ----- 0
All the sounds currently played except for the channel messages are muted when receiving this
message.
<RESET ALL CONTROLLERS> 79H
Cntrl# parameter Data Range
121 ----- 0
Resets the values set for the following controllers.
PITCH BEND CHANGE Center
CHANNEL AFTER TOUCH 0
MODULATION 0
BREATH CONTROLLER Maximum
FOOT CONTROLLER Maximum
EXPRESSION Maximum
CONTROL CHANGE 13 Center
SUSTAIN SWITCH Off
PORTAMENTO SWITCH Off
SOSTENUTO SWITCH Off
RPN Null
Resets the Portamento Control setting.
<ALL NOTES OFF> 7BH
Cntrl# parameter Data Range
123 --------- 0
All the notes currently set to on in a certain channel are muted when receiving this message.
However, if Hold 1 or Sostenute is on, notes will continue sounding until these are turned off.
<OMNI MODE OFF> 7CH
Cntrl# parameter Data Range
124 --------- 0
Performs the same function as when receiving ALL NOTES OFF.
<OMNI MODE ON> 7DH
Cntrl# parameter Data Range
125 ----- 0
Performs the same function as when receiving ALL NOTES OFF.