Owner`s manual

– 39 –
STORAGE
Long term storage of your generator will require some
preventive procedures to guard against deterioration.
DRAIN THE FUEL
1. Turn the engine switch to “STOP”.
1 5 “STOP”
A EF3000iS
B EF3000iSE, EF3000iSEB
2. Remove the fuel tank cap and the fuel tank filter.
Extract the fuel from the fuel tank into an approved
gasoline container using a commercially available
hand siphon. Then, install the fuel tank filter and
the fuel tank cap.
Fuel is highly flammable and poisonous. Check
“SAFETY INFORMATION” (See page 4) carefully.
Immediately wipe off spilled fuel with a clean, dry,
soft cloth, since fuel may deteriorate painted sur-
faces or plastic parts.
3. Turn the fuel cock knob to “ON”.
1 “ON”
4. Start the engine and leave it run until it stops.
The engine stops in approximately 20 minutes time
by running out of fuel.
TIP
9 Do not connect with any electrical devices.
(unloaded operation)
9 Duration of the running engine depends on the
amount of the fuel left in the tank.
5. Remove the screw, and then remove the cover.
1 Screw
2 Cover
NOTICE
WARNING
1
705-073b
ON
OFF
1
788-003a
1
2
763-120b
1
A
B
7CH-9-15-b 11.12.6 10:43 AM Page 39