BATTERY CHARGING
Do not connect a VRLA (Valve Regulated Lead
Acid) battery. To charge a VRLA battery, a special
(constant-voltage) battery charger is required.
TIP
9 The generator DC rated voltage is 12V.
9 Start the engine first, and then connect the gener-
ator to the battery for charging.
9 Before starting to charge the battery, make sure
that the DC protector is turned RESET.
1. Start the engine.
2. Press in the DC protector.
1 RESET
2 OFF
3. Connect the red battery charger lead to the posi-
tive (+) battery terminal.
1 Red wire
2 Black wire
4. Connect the black battery charger lead to the neg-
ative () battery terminal.
5. Turn the economy control switch OFF to start
battery charging.
NOTICE
18
1
2
1
2
763-005a
7VU-9-16-A 2/18/11 9:45 AM Page 18