Battery charging
Do not connect a VRLA (Valve Regulated Lead
Acid) battery. To charge a VRLA battery, a special
(constant-voltage) battery charger is required.
TIP
9 The generator DC rated voltage is 12V.
9 Start the engine first, and then connect the gener-
ator to the battery for charging.
9 Before starting to charge the battery, make sure
that the DC protector is turned on.
1. Start the engine.
2. Press in the DC protector.
1 “ON”
2 “OFF”
NOTICE
3. Connect the red battery charger lead 1 to the pos-
itive (+) battery terminal.
1 Red wire
2 Black wire
4. Connect the black battery charger lead 2 to the
negative (-) battery terminal.