User Manual
Table Of Contents
Reference
34
Function Category Settings Default value Setting range
Full range Subwoofer
Page 
number
Standard Dante Standard Dante
METER Input Meter Shows analog input signal levels. (On 
Dante models this will appear as 
ANA.)
— -∞ to 0dBFS  (×2)  (×2)  (×2)  (×2) 11
Input Meter (DNT) Shows digital input signal (Dante) lev-
els.
— -∞ to 0dBFS  (×2)  (×2) 11
UNIT ID Shows the ID assigned so that DZR-D 
or DXS-XLF-D series devices on the 
Dante network can be recognized.
01 01 to FE 
11, 24, 
25
LABEL Shows the label. — 12 characters 11, 24
MASTER Level Sets the output level. (Unit: dB) 0.0dB -∞, -80 to +10.0dB    11
SP Output Meter Shows the output level. — -∞ to 0dBFS     11
Protection 
(THERMAL, MUTED)
Appears when safeguard functions 
have been activated.
Hidden THERMAL, MUTED 11
MUTED from REMOTE Mutes audio from an external device. Off — 28
Function Category Parameter Default value Setting range
Full range Subwoofer
Page 
number
Standard Dante Standard Dante
TUNING HPF OFF, 60Hz, 70Hz, 80Hz, 90Hz, 100Hz, 
110Hz, 120Hz
OFF 60Hz to 120Hz  11, 15
LPF 60Hz, 70Hz, 80Hz, 90Hz, 100Hz, 
110Hz, 120Hz
120Hz 60Hz to 120Hz 
11, 15
POLARITY NORMAL NORMAL, INVERTED 
D-CONTOUR OFF (NORMAL), FOH/MAIN, MONI-
TOR
OFF (NORMAL)
OFF (NORMAL), FOH/MAIN, 
MONITOR
 11, 15
D-XSUB OFF (NORMAL), BOOST, XTEND LF OFF (NORMAL) OFF (NORMAL), BOOST, XTEND LF 11, 16
EQ (6 bands) ON, OFF ON ON, OFF 
11, 16
BYPS <Bypass> ON ON, OFF  (×6)  (×6)  (×6)  (×6)
FREQ <Frequency> <Each Band> 20.0Hz to 20.0kHz  (×6)  (×6)  (×6)  (×6)
GAIN 0.0 -10.0 to +10.0dB  (×6)  (×6)  (×6)  (×6)
Q 2.00 0.7 to 10.0  (×6)  (×6)  (×6)  (×6)
TYPE PEQ
PEQ, LO SHELF 6dB, 
LO SHELF 12dB, HI SHELF 6dB, 
HI SHELF 12dB, HPF, LPF
 (×6)  (×6)  (×6)  (×6)
DELAY ON, OFF ON ON, OFF 
11, 16
ms 0.0ms 0.0 to 140.0ms 
m 0.00m 0.00 to 48.10m 
ft 0.0ft 0.0 to 157.8ft 
CARDIOID OMNI (FRONT), CARDIO-2 (REAR), 
CARDIO-3 (REAR)
OMNI (FRONT)
OMNI (FRONT), CARDIO-2 (REAR), 
CARDIO-3 (REAR)
11, 17
Function Tree