Specifications
5. Locations & connections
Locations
AlllocationsinthesystemfeaturetwoGigabitmanaged
switches.CobraNet™andEthernetdevicesareconnected
tospecicconnectorsoftheswitches.
Installations
Forinstallations,thenetworkconnectionsoftheswitches
canbeused.Nofrontpanelconnectorsarerequired.
Touring
In case of a 19” rack, the two top units carry the two
switches. The back side allows access to the switch
ports, the front side includes touring connectivity using
EtherCon
®
connectorsforCAT5EcablingandFiberfox
®
EBC52connectorsforbercabling.
In case of a mixing console, the switches, EtherCon
®
and Fiberfox
®
connectors can be built into the mixer’s
ightcase,e.g.inthedogboxattherearoftheconsole.
Star location
A high capacity switch, such as theDlink DGS3324SR,
featuring24Gigabitportswithfour GBIC SFP slotsfor
berconnectivity,isusedforthestarlocation.Ports1to
8 are allocated toVLAN1: default (the controlVLAN).
Ports9 to16are allocatedtoVLAN2:CobraNet™. For
redundancyoneCAT5Epatchcableconnectstoport17of
bothswitches.Ports21to24doublewiththeGBICslots
forconnectiontotheendlocations.
Fortouringapplications,eachlocationtobeconnectedto
thestarrequirestwoconnectorsonthefrontpanelofthe
location’scase:twoEtherCon
®
connectorsforredundant
CAT5EcablingortwoFiberfox
®
EBC52connectorsfor
redundantbercabling.
End locations
A low capacity switch, suchas the DlinkDES-3010GA,
featuring eight 100Mb ports, one Gigabit port and one
GBICSFPslotfor ber connectivity, isusedforallend
locations.Thisswitchdoesnothaveafansoitissilent;it
canbeusedincriticalacousticenvironments.
Ports1and2areallocatedtoVLAN1:default(thecontrol
VLAN).Ports3to8areallocatedtoVLAN2:CobraNet.
For locationswith Fiberconnectivity, one CAT5E patch
cableconnects theTX Gigabitports of bothswitches to
support the RSTP redundancy, while the GBIC slot is
usedfor connectionwith thestar location.For locations
with CAT5E connectivity the GBIC slot is used for the
RSTP redundancylink, and theTX Gigabit port for the
connectionwiththestarlocation.
Fortouringapplications,twoconnectorsareavailableon
thefrontpanels:twoEtherCon
®
connectorsforredundant
CAT5EcablingortwoFiberfox
®
EBC52connectorsfor
redundant ber cabling.An end location can connect to
furtherCobraNet™devices,otherthanthosebuiltinthe
stagerack,usingtwoEtherCon
®
connectorsperdevice.
Redundancy
Allconnectionscomeinpairsforredundancy.Connections
shouldberolledoutphysicallyseparatedfromeachother
as much as possible to offer maximum protection from
cablingaccidentse.g.involvingrodentsorheavymilitary
equipment.
Starlocationrackfrontview
Endlocationrackfrontview
Starlocationrackrearview Endlocationrackrearview Locationfunctionaldiagram
Rack contents
Rack contents
Rack contents
Rack contents