Owner's Manual
Table Of Contents
- Foreword
- Introduction to the DME64N/24N
- The Controls and Connectors
- Preparation
- Connecting to a Computer
- Audio I/O Connection
- Connecting to an External Device
- Panel Operation and Displays
- Basic Operation
- Main Display
- Parameter Edit Displays
- Spectrum Display
- Level Meter Display
- Initializing the DME64N/ DME24N
- Utility Displays
- Items accessible via the Utility display
- Utility Display Operation
- Info Page
- Network Settings (Net) Page
- Display Setup (Disp) Page
- Security Setup (Lock) Page
- Miscellaneous Setup (Misc) Page
- Word Clock Setup (WCLK) Page
- Slot Information (Slot) Page
- MIDI Setup (MIDI) Page
- GPI Setup (GPI) Page
- Head Amplifier Setup (HA) Page
- Cascade Setup (CASCAD) Page
- Check Page
- References
- Index

References
MIDI Data Format
DME64N/DME24N Owner’s Manual
67
4.1 Program Change (Cnh)
Receive
When the “Program Change Rx Switch” is on, Program Change messages are received on the MIDI channel specified by
the “MIDI Rx Channel” parameter.
If the “Program Change Omni Switch” is also on, however, Program Change messages will be received on all MIDI
channels regardless of the “MIDI Rx Channel” setting.
When a Program Change message is received, the scene assigned to the received program number in the “MIDI Program
Change table” is recalled.
The accepted Bank Select, Program Change range is as follows:
Bank Select MSB: 0
Bank Select LSB: 0 ~ 7
Program Change No.: 0 ~ 127
Transmit
When the “Program Change Tx Switch” is on, the corresponding Program Change number will be transmitted as specified
by the “MIDI Program Change table” and “MIDI Tx Channel” settings.
Transmission does not occur when switching Configurations.
If multiple Program Change numbers are assigned to a single scene, the Bank Select MSB/LSB and Program Change
number corresponding to the lowest number will be transmitted.
Bank Select MSB
Bank Select LSB
Program Change No.
4.2 Active Sensing (FEh)
Receive
MIDI communication will be initialized if no data is received within 300 ms after reception (Running Status, etc., will be
cleared).
Active Sensing
4.3 Control Change (Bnh)
Receive
When the “Control Change Rx Switch” is on, Control Change messages are received on the MIDI channel specified by the
“MIDI Rx Channel” parameter.
If the “Control Change Omni Switch” is also on, however, Control Change messages will be received on all MIDI channels
regardless of the “MIDI Rx Channel” setting.
Control Change parameter resolution is 128 regardless of the parameters effective range. For finer settings use Parameter
Change.
Transmit
When the “Control Change Tx Switch” is on, appropriate Control Change data will be transmitted when a parameter is
edited via the panel controls, as specified by the “MIDI Control Change table” and “MIDI Tx Channel” settings.
Transmission does not occur when switching Configurations.
Refer to “Supplementary Information 1” for cases in which multiple messages are assigned to single parameter.
4.4 Parameter Change (F0h ~ F7h)
Receive
When the “Parameter Change Rx Switch” is On, Parameter Change messages are received on the MIDI channel specified
by the “Device ID (Rx Ch)” parameter.
Status Bnh (1101nnnnb) Control Change
Data 00h (00000000b) Control Change No. 0 (Bank Select MSB)
Data nnh (0nnnnnnnb) Control Value (Bank Select MSB No.)
Status Bnh (1101nnnnb) Control Change
Data 20h (00100000b) Control Change No. 32 (Bank Select LSB)
nnh (0nnnnnnnb) Control Value (Bank Select LSB No.)
Status Cnh (1100nnnnb) Program Change
Data nnh (0nnnnnnnb) Program Change No. (0-127)
Status FEh (11111110b) Active Sensing
Status Bnh (1011nnnnb) Control Change
Data cch (0cccccccb) Control Change No. (1-31,33-95,102-119)
vvh (0vvvvvvvb) Control Value (0-127)