Owner's Manual
Table Of Contents
- Foreword
- Introduction to the DME64N/24N
- The Controls and Connectors
- Preparation
- Connecting to a Computer
- Audio I/O Connection
- Connecting to an External Device
- Panel Operation and Displays
- Basic Operation
- Main Display
- Parameter Edit Displays
- Spectrum Display
- Level Meter Display
- Initializing the DME64N/ DME24N
- Utility Displays
- Items accessible via the Utility display
- Utility Display Operation
- Info Page
- Network Settings (Net) Page
- Display Setup (Disp) Page
- Security Setup (Lock) Page
- Miscellaneous Setup (Misc) Page
- Word Clock Setup (WCLK) Page
- Slot Information (Slot) Page
- MIDI Setup (MIDI) Page
- GPI Setup (GPI) Page
- Head Amplifier Setup (HA) Page
- Cascade Setup (CASCAD) Page
- Check Page
- References
- Index

References
Error Messages
DME64N/DME24N Owner’s Manual
56
Error Messages
Message Meaning Action
Error messages
Cannot Select No selectable items are available in the scene or
monitoring point list display.
Make the appropriate settings via the DME Designer
application.
Critical Battery The internal battery is almost discharged. Your data may
be lost.
If you turn off power to the unit, the current settings may
be lost and reset to the default values. Stop operating the
unit, and contact a Yamaha dealer for battery
replacement.
Flash Rom Full The flash ROM is full. Reduce the number of stored scenes.
Invalid Password An invalid password has been entered. Enter the correct password. If you have lost or forgotten
your password, contact your Yamaha service center or
representative.
Low Battery The backup battery voltage is low. This does not affect the operation of the unit. However, if
you continue using the unit, the settings may be lost and
reset to the default values. Contact a Yamaha dealer for
battery replacement at your earliest convenience.
MIDI Port In Use The MIDI port setting is set to the same setting as the
DME Designer application.
Set the Utility MIDI page "Port" parameter to a different
port.
No Battery The internal battery is completely discharged or not
installed.
If you turn off the power to the unit, the current settings
will be lost and reset to the default values. Stop operating
the unit, and contact a Yamaha dealer for battery
replacement.
Param Access Err Current setting cannot be displayed. Try again.
Param Set Err Current setting cannot be changed. Try again.
Resume Data Lost!
Recall a Scene!
Current setting has been lost. Recall the scene again.
If the problem persists, contact a Yamaha dealer.
Saving Failed A save operation has failed. Stop using the device immediately and contact your
Yamaha service center or representative.
Slots Overloaded The current being used by all cards installed in I/O slots
exceeds the rated limit.
Make sure that the total current consumption of the cards
used does not exceed the limit.
Store Disable The scene store parameter is set to "Disable." Set the scene store parameter to "Enable" via the Utility
display "Lock" page.
Status messages
Cable Disconnect No network cable connected. Make sure that a network cable is properly connected,
and that all network devices are functioning normally.
Cannot be assigned No parameter assigned. —
Cannot Store The scene data is protected. Set the protect parameter to "OFF" via the DME Designer
application.
CAS. In Sync Err The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE IN] connector.
Make sure that the DME64N/24N and the card or
external source supplying the word clock are set to use
the same word clock.
CAS. Out Sync Err The DME64N/24N clock is not in sync with the clock
signal being received at the [CASCADE OUT] connector.
Make sure that the DME64N/24N and the card or
external source supplying the word clock are set to use
the same word clock.
Connection to Master
DME is Lost
Communication with the master DME device has been
interrupted.
Check that all cables are properly connected, and than
hubs, routers, and related evices are functioning
properly.
Connection to Slave
SME is Lost
Communication with the slave DME device has been
interrupted.
Check that all cables are properly connected, and than
hubs, routers, and related evices are functioning
properly.
Download Success The program has been successfully updated. —
Downloading
Do not turn off
Program update in progress. Do NOT turn power off
while the unit displays this message.
—
DSP Power Shortage Audio is not input or output and is muted due to
insufficient DSP resources.
This error sometimes occurs if you try to operate a
configuration at 96 kHz that has been created with a
word clock of 48 kHz. To operate a configuration at any
word clock setting, use DME Designer to create a
configuration with the word clock set to 96 kHz.
Dupulicate IP Adr. Duplicate IP addresses. Change the IP addresses so that there are no duplicates.
Err: Wrong Device
Group Settings
The device group configuration set via DME Designer
does not match the actual configuration.
Use DME Designer to go off-line, create a configuration
that correctly matches the actual configuration, and then
go back on-line to synchronize the configuration.
Executing Direct setup from the User Defined Buttons in progress. —
File Opening
Do not turn off
A file operation is in progress during which the computer
manipulates scene data. Do NOT turn power off
while the unit displays this message.
—