Error Messages
DME64N/24N Owner’s Manual
62
Saving Setup Info Info set up via the Utility display (other than head
amplifier info) is being saved.
(Do not turn power off.)
None required.
Scene Recalling Scene recall in progress. None required.
Scene Storing Scene store in progress.
(Do not turn power off.)
None required.
SLOT1 Sync Err The DME64N/24N clock is not synchronized with the
clock of the card installed in I/O slot 1.
Make sure that the DME64N/24N and the card installed
in I/O slot 1 are set to use the same word clock.
SLOT2 Sync Err The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 2.
Make sure that the DME64N and the card installed in I/O
slot 2 are set to use the same word clock.
SLOT3 Sync Err The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 3.
Make sure that the DME64N and the card installed in I/O
slot 3 are set to use the same word clock.
SLOT4 Sync Err The DME64N clock is not synchronized with the clock of
the card installed in I/O slot 4.
Make sure that the DME64N and the card installed in I/O
slot 4 are set to use the same word clock.
WCLK Unlocked A usable word clock signal is not being received or
cannot be detected.
Recheck all word clock connections and internal
parameters.
Zone Sync Err The DME64N/24N contains data of another zone or no
data.
Send appropriate data from a computer running the DME
Designer application,
Message Meaning Action