Owner's Manual

Appendix
Options
DME64N/24N Owner’s Manual
59
CP4SW, CP4SF, and CP1SF
These controllers connect to the DME64N/24N via its GPI interface. These controllers only control the
DME64N/24N unit to which they are directly connected.
The CP4SW is a four-switch unit with four indicator LEDs, while the CP1SF and CP4SF have one and four
faders, switches, and LEDs, respectively. The parameters to be controlled by the switches and faders on these
controllers can be specified via the DME Designer.
Installation
Please have the CP4SW, CP1SF, and/or CP4SF installed by a Yamaha-qualified contractor. Consult your
Yamaha representative.
Cable
Cable lengths up to 100 meters can be used to connect to the DME64N/24N if CPEV cable with a conductor
diameter of greater than 0.65 millimeters is used.
Bare cable ends to be connected to the Euroblock as shown in the diagram.
Be sure to use shielded cable.
Do not tin (plate with solder) the exposed sections of the cable.
NOTE
Refer to “Euroblock Connection” on page 35 for instructions on connecting cables to the Euroblock connectors.
CONTROL PANEL
CP4SW
10
0
CONTROL PANEL
CP1SF
10
0
10
0
10
0
10
0
CONTROL PANEL
CP4SF
CP4SF CP1SFCP4SW
Fader
Fader
Switch
Switch
LED
LED
LED
LED
LED
Switch
7mm
7mm
Single conductor. Twisted pair. Shielded cable.