Control from a Computer Having the Same Network Address
Control from a Computer Having a Different Network Address
NOTE
The IP addresses in the diagram are examples.
NOTE
Use a switching hub that is compatible with 100Base-TX/10Base-T network speeds.
When using category 5 UTP cable (Unshielded Twisted Pair), the total length of the cables connecting the DME64N/24N to
the hub or control panel unit can be up to 100 meters. Due to differences in cable and switching hub performance, however,
proper operation at the maximum length cannot be guaranteed in some cases. The maximum usable cable length will also be
reduced if joint connectors, cross cable converters, or other extension adaptors are used.
DME64N/24N
DME64N/24N DME64N/24N
Zone
Zone Master
Ethernet Straight Cable
Ethernet Straight Cable
Ethernet
Straight Cable
Computer
(IP Address: 192.168.0.100)
Switching Hub
Ethernet
Straight Cable
(IP Address: 192.168.0.2)
(IP Address: 192.168.0.3) (IP Address: 192.168.0.250)
DME64N/24N
DME64N/24N
DME64N/24N
Zone Master
Ethernet Straight Cable
Ethernet
Straight Cable
Computer
Router
Ethernet
Straight Cable
Ethernet
Straight Cable
Zone
(IP Address: 192.168.0.2)
Ethernet
Straight Cable
Switching Hub
(IP Address: 192.168.0.3)
(IP Address: 192.168.0.12)
Port Settings
• Destination network address: 192.168.0.0
• Subnet mask: 255.255.255.0
• Gateway: 192.168.0.1