Owner's Manual

DME64N/24N Audio System Overview
DME64N/24N Audio System Control
DME64N/24N Owner’s Manual
14
DME64N/24N Audio System Control
To facilitate understanding and controlling an overall DME64N/24N system, the terms “component,” “parameter,” “scene,”
and “user-defined parameter” are applied.
Components & Parameters
The individual audio modules (equalizers, compressors, etc.) are called “components.” Head amplifier modules
are also prepared as components. Changing the parameters of components enables control over the operation
of the components.
Configurations
A “configuration” is a complete set of components for constructing an audio system. Each configuration
determines the audio function(s) of the corresponding DME64N/24N unit. All parameter sets included with
each component are called “preset parameters.” One DME64N/24N unit has a number of configurations, and
a configuration has a number of preset parameters.
User-defined Parameters
By assigning a parameter to a user-defined parameter, the user-defined parameter can be controlled from the
panels of the DME64N/24N and ICP1, or other controllers connected via MIDI or GPI. Multiple parameters
assigned to a single user-defined parameter will be controlled simultaneously. Up to 24 user-defined parameters
can be used in a zone.
Scenes
A combination of all configuration and preset parameter combinations is called a “scene.” A scene determines
the audio effect(s) in the zone. Scenes can be recalled from the panels of the DME64N/24N and ICP1, other
controllers connected via MIDI or GPI, or computer control. Up to 999 scenes can be stored for each zone.
Scene Structure
Scene Change
NOTE
Slight delays might be experienced when switching scenes or editing user-defined parameters, depending on the network
condition.
MATRIX MIXER PARAMETRIC EQ
PARAMETRIC EQ
DELAY DELAYCROSSOVER
2WAY
COMP/LIMITER
PARAMETRIC EQ
DELAY CROSSOVER
2WAY
COMP/LIMITER
COMP/LIMITER GATE
PARAMETRIC EQ
DELAY COMP/LIMITER GATE
PARAMETRIC EQ
DELAY COMP/LIMITER GATE
PARAMETRIC EQ
DELAY COMP/LIMITER GATE
16 x 8
8 BAND
Scene Configuration
Scene 1
Scene 2
Scene 999
= Component
Preset
Parameters
Example:
Gate
• Attack
• Decay
• Range
• Threshold
• Key In
• Hold
:
:
First Act
Band Setup
Theater Setup
Stage
Scene 1
Stage Lights Down
Second Act
Scene Recall Scene 2
Band Setup
Band
Setup
Theater Setup
Theater
Setup
Stage
Stage