User Manual
Table Of Contents
- Table of contents
- Introduction
- Controls and functions
- Overview of screens
- HOME screen
- DAW REMOTE screen
- Channel-specific screens
- Other fixed display areas
- MAINTENANCE screen
- Operating Screens
- SCENE screen
- RECORDER screen
- MONITOR screen
- SETUP screen
- LOGIN screen
- HOME screen
- DAW REMOTE screen
- Channel-specific screens
- Adjusting EQ in manual mode
- Adjusting EQ in 1-knob mode
- Configuring the HPF
- Configuring GATE/DUCKING
- Adjusting the compressor in manual mode
- Adjusting the compressor in 1-knob mode
- Setting effects
- Adjusting the send to MIX/MATRIX BUS level
- Setting the send to FX BUS level
- Adjusting the send to FX/MIX/MATRIX BUS level with faders
- Using GEQ
- Using faders to adjust GEQ
- Configuring mute safe
- Setting the send levels from output channels (MIX, STEREO) to MATRIX
- Recall presets
- Editing presets
- MAINTENANCE screen
- DM3 Editor
- Using the Editor
- Appendix
d
Key In channel selection button
It is enabled when Other Ch or MIX are selected by the Key In selection button.
When Other Ch is selected, select from CH 1-16 Post EQ.
When MIX is selected, select from MIX OUT 1-6.
e
CUE button
Turns the Key In signal CUE ON/OFF.
f
DYN1 Key In level meter
Displays the Key In input level.
g
DYN1 input level meter
Displays the DYN1 input level.
h
Threshold slider
Determines the level at which the GATE/DUCKING effect is applied.
i
GATE/DUCKING graph
Displays a visual representation of the GATE/DUCKING level.
j
Range slider
Determines the amount by which the signal will be lowered when GATE/DUCKING is applied.
k
Attack slider
When GATE is selected, this sets the time from when the input signal exceeds the threshold level until the gate opens.
When DUCKING is selected, this sets the time from when the input signal exceeds the threshold level until the gate
closes.
l
Decay slider
When GATE is selected, this sets the time until the gate closes after the input signal has passed the HOLD waiting
time. When DUCKING is selected, this sets the time until the gate opens after the input signal has passed the HOLD
waiting time. The setting value expresses the time required for the level to change by 6 dB.
m
Hold slider
When GATE is selected, this sets the waiting time until the gate starts to close after the input signal falls below the
threshold level. When DUCKING is selected, this sets the waiting time until the gate starts to open after the input
signal falls below the threshold level.
n
GR (gain reduction) meter
Displays the amount by which the signal's gain is reduced.
o
OUT (output) meter
Displays the GATE/DUCKING output level.
n
DYN1 screen menu
Swipe left on the menu swipe indicator on the right of the DYN1 screen to open the following menu.
182
Channel-specific screens > DYN1 (GATE/DUCKING) screen










