K0/K1 (Panel key of main unit)
A/D of the key fails to function properly when the standard
value is deviated by ±2%. In this case, check the constant
of voltage dividing resistor, solder condition, etc.
(Reference voltage: 3.3V=100%)
K0/K1 (本体パネルキー)




[%]
0+2
10±2
100-2
K0
VOLUME +
INPUT
NO KEY
K1
VOLUME -
NO KEY
K0:100 K1:099
9. AD DATA CHECK
This menu is used to display the A/D conversion value
of the main microprocessor which detects panel keys
of the main unit and protection functions in % using the
sub-menu. During signal processing, the condition
before execution is maintained.
PS (Power supply voltage protection detection)
* When the value of PS, P2 and P3 is not at the normal
value level, the protection function works and the power
is turned off.
(Reference voltage: 3.3V=100%)
PS (PS1) Voltage detects: -24 V, +5.3X (B model),
+5 V, +5I (A, B models)
Normal value: 48.7 to 91.3 %
(1.6 to 3.0 V)
P2 (PS2) Voltage detects: +12 V, T+10 (K, A, G, E,
L, V models), D+12
Normal value: 63.9 to 88.2 %
(2.1 to 2.9 V)
P3 (PS3) Voltage detects: +3.3 V
Normal value: 66.9 to 85.2 %
(2.2 to 2.8 V)
* The normal value has been revised from 2.5V
(measured value) to 3.3V (indicated value) by the
voltage dividing resistor.
9. AD DATA CHECK



PS (電源電圧プロテクションの検出)



PS(PS1) 
 
P2(PS2) 
 
P3(PS3) 
 
 

PS:077%[2.54V]
P2:076%[2.50V]
P3:076%[2.50V]