Service manual
Table Of Contents
- CONTENTS
- TO SERVICE PERSONNEL
- FRONT PANELS
- REAR PANELS
- REMOTE CONTROL PANELS
- SPECIFICATIONS
- INTERNAL VIEW
- SET MENU TABLE
- SERVICE PRECAUTIONS
- DISASSEMBLY PROCEDURES
- UPDATING FIRMWARE
- SELF-DIAGNOSTIC FUNCTION
- Starting Self-Diagnostic Function
- Starting Self-Diagnostic Function in the protection cancel mode
- Canceling Self-Diagnostic Function
- Display provided when Self-Diagnostic Function started
- Display during Self-Diagnostic Function operation
- Operation procedure of Main menu and Sub-menu
- Functions in Self-Diagnostic Function mode
- Initial settings used to start Self-Diagnostic Function
- Details of Self-Diagnostic Function menu
- 1. DSP THROUGH
- 2. RAM THROUGH
- 3. PRO LOGIC / Neo:6
- 4. MIC CHECK
- 5. VFD CHECK
- 6. MANUAL TEST
- 7. RS-232C
- 8. FACTORY PRESET
- 9. AD DATA CHECK
- 10.IF STATUS (Input function status)
- 11.DOCK CHECK
- 12.XM CHECK
- 13.DAB CHECK
- 14.HDMI AUDIO
- 15.HDMI INFORMATION
- 16.HDMI SELECT
- 17.VIDEO CONVERSION
- 18.MODEL
- 19.VERSION/CHECK SUM
- 20.DATE
- 21. DSP CHECK
- DISPLAY DATA
- IC DATA
- BLOCK DIAGRAM
- PRINTED CIRCUIT BOARDS
- PIN CONNECTION DIAGRAMS
- SCHEMATIC DIAGRAMS
- REPLACEMENT PARTS LIST
- REMOTE CONTROL
- Adjusting the system parameters

YSP-500/HTY-750
36
YSP-500/HTY-750
6. MANUAL TEST
The noise generator with a built-in DSP outputs the
test noise through the channels specified by the sub-
menu.
The noise frequency is 30 to 80Hz for LFE but 500 to
2kHz for others.
6. MANUAL TEST
TEST ALL TEST FRONT L TEST CENTER
TEST FRONT R TEST SURROUND R TEST SURROUND L
TEST LFE
6.TEST ALL
6.TEST FRNT R
6.TEST LFE
6.TEST FRNT L
6.TEST SURR R
6.TEST CENTER
6.TEST SURR L
Noise is output from all channels.
Noise is output from the FRONT L channel.
Noise is output from the CENTER channel.
Noise is output from the FRONT R channel.
Noise is output from the SURROUND R channel.
Noise is output from the SURROUND L channel.
Noise is output from the SUBWOOFER channel.