Service manual
Table Of Contents
- CONTENTS
- TO SERVICE PERSONNEL
- FRONT PANELS
- REAR PANELS
- REMOTE CONTROL PANELS
- SPECIFICATIONS
- INTERNAL VIEW
- SET MENU TABLE
- SERVICE PRECAUTIONS
- DISASSEMBLY PROCEDURES
- UPDATING FIRMWARE
- SELF-DIAGNOSTIC FUNCTION
- Starting Self-Diagnostic Function
- Starting Self-Diagnostic Function in the protection cancel mode
- Canceling Self-Diagnostic Function
- Display provided when Self-Diagnostic Function started
- Display during Self-Diagnostic Function operation
- Operation procedure of Main menu and Sub-menu
- Functions in Self-Diagnostic Function mode
- Initial settings used to start Self-Diagnostic Function
- Details of Self-Diagnostic Function menu
- 1. DSP THROUGH
- 2. RAM THROUGH
- 3. PRO LOGIC / Neo:6
- 4. MIC CHECK
- 5. VFD CHECK
- 6. MANUAL TEST
- 7. RS-232C
- 8. FACTORY PRESET
- 9. AD DATA CHECK
- 10.IF STATUS (Input function status)
- 11.DOCK CHECK
- 12.XM CHECK
- 13.DAB CHECK
- 14.HDMI AUDIO
- 15.HDMI INFORMATION
- 16.HDMI SELECT
- 17.VIDEO CONVERSION
- 18.MODEL
- 19.VERSION/CHECK SUM
- 20.DATE
- 21. DSP CHECK
- DISPLAY DATA
- IC DATA
- BLOCK DIAGRAM
- PRINTED CIRCUIT BOARDS
- PIN CONNECTION DIAGRAMS
- SCHEMATIC DIAGRAMS
- REPLACEMENT PARTS LIST
- REMOTE CONTROL
- Adjusting the system parameters

YSP-500/HTY-750
28
YSP-500/HTY-750
プロテクション履歴がない場合:
The FL display of the main unit displays the protection
function history data and the version (1 alphabet) and the
self-diagnostic function menu [sub-menu (THR ALL) of
main menu No.1 DSP THROUGH] a few seconds later.
When there is no history of protection function:
NO PROTECT C 1.DSP THR ALL
Version (1 alphabet)
• Display provided when Self-Diagnos-
tic Function started
When the monitor is connected, the list of main menu
items is displayed on the monitor screen as shown below.
(This list remains on display until the self diagnostic
function is cancelled.)
● ダイアグ起動時の表示
When there is a history of protection function: プロテクション履歴がある場合:
After a 5 seconds /
Main menu display / Opening message /
PS PRT:000 C
Version (1 alphabet)
Voltage display in %
P2 PRT:000 C
P3 PRT:000 C
Cause: The voltage in the power supply section is abnormal.
Supplementary information: The abnormal voltage is
displayed in % based on 3.3V as 100%.
Turning on the power without correcting the cause will
trigger the protection function to work 1.5 second later to
shut off the power supply.