User Manual

CobraNet Page 18
NetworkAmp Manager—Owner’s Manual
5 ACU Pages
This chapter explains the ACU pages, which can be selected while an ACU16-C is selected
in the network tree.
Devices on a CobraNet network transmit and receive audio data by matching bundle num-
bers. Matching the bundle number on the transmitting and receiving devices is analogous
to making a physical cable connection between two devices. For example, if the Transmit
bundle assignment (CobraNet Output) on an NHB32-C is set to bundle #4, and the Receive
bundle assignment (CobraNet Input) on an ACU16-C is also set to bundle #4, audio data
in bundle #4 will be carried from the NHB32-C to the ACU16-C.
CobraNet Page
This page is used to assign CobraNet bundles.
You can specify which bundles you want the ACU16-C to receive. The ACU16-C supports
bundles 0 through 16,383 (multicast and unicast). Bundle 0 is not really a bundle as such,
more of a null setting used to disable transmission or reception.
Enable unicast: When this option is unselected, multicast bundles 0 through 255 can be
specified. When it’s selected, bundles 0 through 16,383 can be specified. Bundles 256
through 16,383 are unicast bundles.
Receive bundle assignment: These parameters are used to specify the bundles that
contain the CobraNet channels you want to patch to the ACU16-C’s analog outputs. You
can patch the individual channels in each bundle on the ACU Patch page (see
page 19).