Use, Care, and Installation Guide RH00529S RH00538S DEC10.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Speci cations ............................................................... Electrical ......................................................................... Installing the Power Pack ........................................ 5 6 7 8 9 10 FEATURES & CONTROLS Controls .......................
Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
Always leave safety grilles and lters in place. Without these components, operating blowers could catch onto hair, ngers and loose clothing. The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to negligence and the warranty of the unit automatically expires due to improper maintenance.
List of Materials MODELS: RH00529S and RH00538S PARTS SUPPLIED 1 - Power Pack 2 - Decorative mesh lters (RH00538S Qty 3) 2 - Halogen light bulbs (RH00538S Qty 4) 1 - Dual internal blower (pre installed) 1 - 8” round adapter 1 - Hardware package HARDWARE PACKAGE CONTENTS Suction Cup (1) M4 x 1” (6) M4 x 8 (4) Wire Caps (3) PARTS NOT SUPPLIED - Ducting, conduit and all installation tools - Cable connector (if required by local codes) - Optional stainless steel hood liner 4
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6” Round 30 Ft. wall cap with damper x( ) = Ft. 6” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap x( ) = Ft. 7”-10” Round, 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect.90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect.45 0 elbow x( ) = Ft. 6” round to 16 Ft. 3-1/ 4” x 10” rect.
Installation – Mounting Height & Clearance Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and re hazard; while hoods mounted too high will be hard to reach and will lose its performance and ef ciency.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certi ed Silver Tape or Duct Tape.
Installation – Speci cations 24 5/8” 14 3/4” 5” 7 3/4” 1 1/2” 29 13/16” RH00529S front 1 5/16” elec. k/o 25 15/16” 6 1/2” CL 14 11/16” 15 13/16” 11 7/16” 2 3/8” 4 3/4” 11 7/16” CL 4 3/8” RH00529S top 13/16” 11 7/16” 2 5/8” 14 11/16” 15 13/16” RH00529S / RH00538S side 33 1/8” 14 3/4” *7 3/4” 2 5/8” A: elec.
WARNING All Electrical work must be performed by quali ed electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
RH00529S RH00538S 34 11/16” 26 1/16” C/L 1. Remove support screw from top of Power Pack before installing into cabinet. FIG 2b 2. Install 8” round adapter to top of Power Pack using (4) M4 x 8 screws. 14 3/4” Installation – Installing the Power Pack ! CAUTION: At least two installers are required due to the weight and size of the hood. 3. Install optional Stainless Steel Liner. Review manual included with liner for more details. C/L cabinet bottom cut-out size FIG 1 4.
III II I 2 Lights Off/Bright/Dim II 0 1 BLOWER ON/OFF/SPEED SELECTION 0 is off, I is low speed, II is medium speed and III is high speed. 2 LIGHTS OFF/BRIGHT/DIM 0 is off, I is bright, and II is dim.
Maintenance – Cleaning and Installing Filters SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/ scoring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain.
CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are dif cult to turn due to prolonged use, rmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove and turn counter clockwise.
Troubleshooting TROUBLESHOOTING PROCEDURES FOR RH00529S AND RH00538S Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch wirings are disconnected. 3. Make sure the wirings at the switch are connected properly. 4.
PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Decorative Mesh Filter (each) Z0B-0023 50200037 Optional Accessories Liner,36” (RH00529S) Liner,42” (RH00529S) Liner,48” (RH00538S) Liner,54” (RH00538S) Liner,60” (RH00538S) AK0806AS AK0842AS AK0848AS AK0854AS AK0860AS To order parts please call 1.888.750.