MILLIVOLT POWER VENT CONTROL MODULE
Connect to Power Vent Cable
Connect to Double Pole Switch Cable
Plug into120v AC Outlet
Connect to TH and TH / TP Tabs on Valve
FIREPLACE IS SUPPLIED
WITH ONE JUNCTION BOX.
ADDITIONAL OUTLETS
MAY BE REQUIRED.
CONSULT A QUALIFIED
ELECTRICIAN.
DOUBLE POLE SWITCH
(SUPPLIED)
NOTE: Double Pole Switch can be replaced
with 120V Double Pole Thermostat. Contact an Electrician for installation.
*In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative).
SWITCH MUST BE “ON” AND POWER VENT BLOWER MUST BE RUNNING FOR APPLIANCE TO OPERATE.
NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION:
Downward vertical vent runs are NOT permitted.
NOTE: MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION:
Downward vertical vent runs are permitted, however, Cold Climate Switch (Standing Pilot
Mode) must not be used.