PVH58 VENTING CONFIGURATIONS
MAX 3ft Below Unit
MIN Venting= 3ft
plus one 90° elbow
with Air Intake
Shutter fully open
MAX Venting = 125ft
plus six 90° elbows
PVH-58
Maximum / Minimum Vent Lengths:
Maximum Vent Length is 125 ft plus six 90° elbows with Air Intake
Shutter fully closed. Termination must not be below unit.
This power vent can be installed up to 3ft below the installed fireplace
on runs less than 100ft and not more than four 90° elbows.
Minimum Vent Length is 3ft plus one 90° elbow with Air Intake Shutter
fully open.
Refer to fireplace manual (51MQ-MAN or 51MQ-MAN-II) for proper
installation of your fireplace.
Minimum clearance to combustibles on venting is 1” unless otherwise stated
in manual.
After 30ft of venting, clearance to combustibles is 1”.
MINIMUM VERTICAL RISE BEFORE FIRST 90° ELBLOW
(Measured from bottom of appliance to center of vent pipe)
MQRB4436 37-1/2"
MQRB5143 51-1/2”
MQRB6961 56-1/2”
Seven 90° elbows are possible if
the total horizontal is not more than
25ft and the vertical does not
exceed 15ft.
Refer to Air Intake Adjustment
section of this manual to adjust Air
Intake Shutter.
NOTE: MODELS EQUIPPPED WITH
MILLIVOLT/ STANDING PILOT
IGNITION:
Downward vertical vent runs are NOT
permitted.
NOTE: MODELS EQUIPPPED WITH
INTERMITTENT PILOT IGNITION:
Downward vertical vent runs are
permitted, however, Cold Climate Switch
(Standing Pilot Mode) must not be used.