MQRB6961 Mantel Clearances
Before installing any mantels it is important to determine the combustibility of its
material(s). There are two types of mantels to consider: Combustible and Non-
Combustible.
A Combustible Mantel is one that consists of material(s) that may discolor,
combust, or lose its integrity in the presence of heat. These types of mantels
must strictly conform to the dimensional requirements shown below.
Conversely, a Non-Combustible Mantel is one that is constructed with material(s)
that will not combust. Check your local codes and regulations to determine whether your mantel is Combustible or Non-Combustible.
The advantage to Non-Combustible Mantels is that it may extend right up to the tile lip of the fireplace. Combustible mantels must
adhere to the dimensional restrictions shown below.
Clearance to Combustibles MQRB6961
Back Shield Kit to Wall 0” [0cm]
Side (from Stand-offs) 0” [0cm]
Floor* 0” [0cm]
Airbox on Flue Side of Unit 1” [25cm]
Minimum Ceiling Height (from bottom of fireplace)
64” [Vertical Venting]
68”[Horizontal Venting-See MQRB6961
Combustible Enclosure Heights page]
Top (from Stand-offs) 0” [0cm]
Top of 90° Bend under 78” Enclosure 6-1/2” (With Wall Thimble Shield
[Z57WTS]) All Vent Systems
Top of 90° Bend over 78” Enclosure 6-1/2” All Vent Systems
Top of Horizontal Pipe 2” All Vent Systems
Side & Bottom of Horizontal Pipe 1” All Vent Systems
Vertical Vent Pipe 1” All Vent Systems
Vertical Vent Pipe 1” Simpson / AmeriVent
/ Selkirk Direct Temp Systems
Mantel Dimensions are from
front face or Non-Combustible
Facing Materials covering
fireplace.
[Steel Stud Framing Shown.]
*Note: If appliance is installed directly on carpeting or other combustible material other than wood flooring, a metal or
wood panel extending the full width and depth of the appliance must be used. Carpet may extend 1 inch above the
floor of the appliance.
-Combustible Objects on Non-
Combustible Mantel Warning-
Combustible objects must not be placed
on a Non-combustible Mantel unless the
mantel meets the dimensional
requirements for a Combustible Mantel.
Refer below to determine whether your
mantel conforms to the requirements of
a Combustible Mantel.