MQRB6961 See Thru Framing
MQRB6961SK Kit is required for a See Thru Installation.
Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace
and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush
with the face of the fireplace (Flat Wall appearance).
Note: If using optional surround, maximum thickness for non-combustible material is 3/4”.
(Continued)
Framed Opening 71-1/2” x 45-1/2”
Framing style shown is for illustration purposes only.
This structure is NOT load bearing.
[Steel Stud Framing Shown]
Fireplace vent MUST maintain min. 1” clearance from combustible (Wood) framing.
However
,
if steel stud framin
g
is used
,
1” vent clearance is not
r
e
q
uired.
Also refer to these sections:
Clearance to Combustibles
Enclosure Heights
Venting
Note: If Combustible (Wood) Framing Studs
are used, they must be rotated to allow
Min.1” Clearance from Airbox.