*In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative).
The above diagram shows how the Power Vent Control Module integrates with the IPI System.
These Connections are the same when accessories are used also (i.e. Remote Control, Fan, etc).
RECOMMENDED METHOD OF CONNECTION:
First ensure the entire IPI system is working properly without connecting any Power Vent components.
Then connect the Power Vent Control Module.
IPI VALVE
584.912 HARNESS & IPI MODULE
ORANGE - NORMALLY
CONNECTS TO VALVE
A
T PV1-
A
POSITION
PLUG PV3-A INTO
GREEN WIRE ON 912 OR
GREEN TH WIRE ON 905
HARNESS
NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION:
Downward vertical vent runs are NOT permitted.
NOTE: MODELS EQUIPPPED WITH INTERMITTENT PILOT IGNITION:
Downward vertical vent runs are permitted, however, Cold Climate Switch (Standing Pilot Mode)
must not be used.
-CONNECT ON/OFF DEVICE-
SWITCH, GREEN TH WIRE
FROM #905 HARNESS FOR
REMOTE CONTROL, ETC
FIREPLACE IS SUPPLIED
WITH ONE JUNCTION BOX.
ADDITIONAL OUTLETS
MAY BE REQUIRED.
CONSULT A QUALIFIED
ELECTRICIAN.