\Çy|Ç|àx fxÜ|xá Installation Instructions Model Numbers: Stock Numbers: Certified to: MQRB4436, MQRB5143, MQRB6961 MQRB4436N, MQRB4436NE, MQRB4436LP, MQRB4436LPE MQRB5143N, MQRB5143NE, MQRB5143LP, MQRB5143LPE MQRB6961N, MQRB6961NE, MQRB6961LP, MQRB6961LPE ANSI Z21.50b-2009, CSA 2.22b-2009, CGA 2.17-M91 This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Table of Contents Table of Contents..................................................................................................................................................................... Recommendations for Finishing of Clean View Linear Products............................................................................................. Pre-installation Questions and Answers........................................................................................................................
MQRB5143 Burner Section: Gas Conversion.......................................................................................................................... MQRB4436 / MQRB5143 Burner Tube Removal / Burner System Removal/Installation Guide.............................................. MQRB4436 / 5143 / 6961 Moving Valve to Other Side of Fireplace........................................................................................ MQRB6961 Burner Section: Gas Conversion...............................
Recommendations for Finishing of Clean View Linear Products Only non-combustible materials may be used over the face of the appliance. We recommend that DUROCK (non-combustible material) be tied in to the entire perimeter of the fireplace for durability. Finishing Recommendations (Obtained from professional construction contractors and finishers): Frame unit with metal studs (minimum 20 gauge).
Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used. The following information applies to the curing process to get the paint fully hard and durable.
Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada. Figure 1 - Mobile Home Installation.
Warnings, Installations and Operations Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States.
• Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they provide a primary heat source. • This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance. NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home. Place a detector about 15ft [4.5m] outside the room that houses your gas appliance.
MQRB4436 / MQRB5143 / MQRB6961 Nailing Tab Guide [Qty] 2 Nailing Tabs are located on each corner of the fireplace. The Nailing Tabs on the MQRB4436, MQRB5143 or MQRB6961 can be used in two ways: Framing Flush with Face of Fireplace -Fireplace to be covered with Non-Combustibles (e.g. Concrete Board) for Flat Wall appearance. 1/2” Drywall Flush with Face of Fireplace –Fireplace and Combustible Wall to be covered with Non-Combustible Materials (e.g. Tile around Fireplace).
MQRB4436: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance. Failure to comply with those requirements can seriously compromise the safety and operation of the fireplace.
MQRB4436 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to right side of unit. Left Burner System Right Burner System All Units Can Be Vented Vertically Horizontal Run With Min.
MQRB4436 -See Thru Framing An MQRB4436SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance). Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Framing Style shown is for illustration purposes only.
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel Framing Studs Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1” Clearance from Airbox.
MQRB4436 Single Sided Framing An MQRB4436BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance). Note: If using optional surround, maximum thickness for non-combustible material is 3/4”. Framing Style shown is for illustration purposes only.
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel Framing Stud Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1” Clearance from Airbox. See “Nailing Tab Guide” and “MQRB4436BK / MQRB5143BK / MQRB6961BK” pages before placing unit into the framed opening.
MQRB4436 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and insulation material to prevent direct contact with the appliance. See Thru or Single Sided Installation For Propane Horizontal installations the venting must be a minimum of two feet vertical off the flue before going horizontal.
Surround Dimensions MQRB4436 • • • The Surround Frames are 1” thick, with a 3/4” space behind the frame. When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”. The Fireplace may be covered up to within 1/2” of the Fireplace Opening with non-combustible materials.
MQRB4436 Facing Material Requirements These specifications are the same for all Models (4436N, 4436NE, 4436LP, 4436LPE). Note: If using Optional Surround, See Surround Clearances Section. [Steel Stud Framing Shown.] Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged. Steel Stud Framing Shown.
MQRB4436 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantels to consider: Combustible and NonCombustible. A Combustible Mantel is one that consists of material(s) that may discolor, combust, or lose its integrity in the presence of heat. These types of mantels must strictly conform to the dimensional requirements shown below.
MQRB5143: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance. Failure to comply with those requirements can seriously compromise the safety and operation of the fireplace. Specifications 1.
MQRB5143 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to right side of unit. Left Burner System Right Burner System All units can be vented vertically Horizontal Run with Min.
MQRB5143 -See Thru Framing An MQRB5143SK Kit is required for a See Thru Installation. Before you begin Framing- Determine for both sides whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance). Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Framing Style shown is for illustration purposes only.
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel Framing Studs Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1” Clearance from Airbox.
MQRB5143 Single Sided Framing An MQRB5143BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance). Note: If using optional surround, maximum thickness for non-combustible material is 3/4”. Framing Style shown is for illustration purposes only.
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel Framing Stud Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1” Clearance from Airbox. See “Nailing Tab Guide” and “MQRB4436BK / MQRB5143BK / MQRB6961BK” pages before placing unit into the framed opening.
MQRB5143 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and insulation material to prevent direct contact with the appliance. See Thru or Single Sided Installation [Steel Stud Framing Shown.
Surround Dimensions MQRB5143 • • • The Surround Frames are 1” thick, with a 3/4” space behind the frame. When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”. The Fireplace may be covered up to within 1/2” of the Fireplace Opening with non-combustible materials.
MQRB5143 Facing Material Requirements These specifications are the same for all Models (5143N, 5143NE, 5143LP, 5143LPE). Note: If using Optional Surround, See Surround Clearances Section. [Steel Stud Framing Shown.] Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged. Steel Stud Framing Shown.
MQRB5143 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantels to consider: Combustible and NonCombustible. A Combustible Mantel is one that consists of material(s) that may discolor, combust, or lose its integrity in the presence of heat. These types of mantels must strictly conform to the dimensional requirements shown below.
MQRB6961: Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance. Failure to comply with those requirements can seriously compromise the safety and operation of the fireplace. 1. 2. 3. 4. 5.
MQRB6961 Locating Your Appliance All units are Factory Set for a Left Hand Burner System. Right Hand Burner System Requires Valve to be relocated to right side of unit.
MQRB6961 See Thru Framing MQRB6961SK Kit is required for a See Thru Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance). Note: If using optional surround, maximum thickness for non-combustible material is 3/4”.
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Studs Steel Framing Studs 19-3/8” 20-3/8” Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be rotated to allow Min.1” Clearance from Airbox. See the “Nailing Tab Guide” and “ MQRB6961SK” pages before placing unit into the framed opening.
MQRB6961 Single Sided Framing An MQRB6961BK Kit is required for a Single Sided Installation. Before you begin Framing- Determine whether the Wall Surface will be flush with the face of the fireplace (Fireplace and wall to be covered with Non-Combustibles, such as tile), or the Framing will be flush with the face of the fireplace (Flat Wall appearance). Note: If using optional surround, maximum thickness for non-combustible material is 3/4”.
Wall Surface Flush With Face of Fireplace Framing Flush With Face of Fireplace [Steel Stud Framing Shown.] Steel Framing Stud Steel Framing Stud Steel Framing Stud Steel Framing Stud Note: If using Optional Surround, Maximum Thickness for Non-Combustible Material is 3/4”. Note: If Combustible (Wood) Framing Studs are used, they must be Rotated to allow Min.1” Clearance from Airbox. *See the “Nailing Tab Guide” and “ MQRB6961BK” pages before placing unit into the framed opening.
MQRB6961 Combustible Enclosure Heights Cold Climate Recommendation When installing this fireplace against an exterior wall or chase, it is recommended that the outer walls be insulated to conform to applicable insulation codes. Drywall must be installed over vapor barrier and insulation material to prevent direct contact with the appliance. See Thru or Single Sided Installation For Propane Horizontal installations the venting must be a minimum of two feet vertical off the flue before going horizontal.
Surround Dimensions MQRB6961 • • • The Surround Frames are 1” thick, with a 3/4” space behind the frame. When using Surrounds, Maximum Thickness for Non-Combustible Facing Materials is 3/4”. The Fireplace may be covered up to within 1/2” of the Fireplace Opening with non-combustible materials.
MQRB6961 Facing Material Requirements These specifications are the same for all Models (6961N, 6961NE, 6961LP, 6961LPE). Note: If using Optional Surround, MQRB6961 See Surround Clearances Section. [Steel Stud Framing Shown.] Note: Do not drive excessively long screws into the face of the unit as internal parts may be damaged. Steel Stud Framing Shown.
MQRB6961 Mantel Clearances Before installing any mantels it is important to determine the combustibility of its material(s). There are two types of mantels to consider: Combustible and NonCombustible. A Combustible Mantel is one that consists of material(s) that may discolor, combust, or lose its integrity in the presence of heat. These types of mantels must strictly conform to the dimensional requirements shown below.
MQRB44BK / MQRB51BK / MQRB69BK Back Shield Kit –Single View *This Kit must be opened before unit is installed into Framing (See “Single Sided Framing” pages of this Manual). Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
Back Liner, False Bottom, and End Panel Installation: 1. Remove Liner Clips from the inside of the Firebox (Fig.1). 2. Place the Back Liner onto the firebox bottom with bends facing the rear firebox cover. Lift into place and set down on firebox ledge (See Fig.2). 3. Next install the False Bottom with larger Dimension to Front Glass Opening (Fig.1), and secure it using DT screws into the mounting tabs on the Burner Tube. Insert Pilot Shield and False Bottom Cover into False Bottom. 4.
MQRB44SK / MQRB51SK / MQRB69SK (See Thru Kit) Installation This basic Kit is required for See Thru installations. Note: To cover the Side Fillers with non-combustible materials, they must be installed before Facing materials are applied. Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. Components: [2ea.
MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation Single Sided: MQRB44PB1, MQRB51PB1, or MQRB69PB1-[1ea.] Porcelain False Bottom MQRB4436PLB, MQRB5143PLB, or MQRB6961PLB-[1ea.] Porcelain Back Liner Panel MQRB4436 (uses 5143PLE), MQRB5143PLE, or MQRB6961PLE-[2ea.] Porcelain End Panels Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
MQRB4436 / MQRB5143 / MQRB6961 Liner & False Bottom Installation See Thru: MQRB44PB2, MQRB51PB2, or MQRB69PB2-[1ea.] Porcelain False Bottom MQRB4436 (Uses 5143PLE), MQRB5143PLE or MQRB6961PLE-[2ea.] Porcelain End Panels False Bottom & End Panel Installation: 1. False Bottom Insert False Bottom into Fireplace. Fasten the False Bottom to the Burner Assembly with [6] DT Screws provided. Insert Pilot Shield into False Bottom. 2. End Panels Remove the Liner Retainer Clips in the Firebox Top.
MQRB4436, MQRB5143 & MQRB6961 Finishing Options Using Side Fillers The Side Fillers are located at each side of the door. They are provided to give a continuous surface up to the opening of the fireplace door. Using Other Non-Combustible Materials as Side Fillers (Brick, Tile, Marble, etc.) Non-Combustible facing materials, such as brick or tile may be used in place of the Side Fillers- so long as the total amount of material applied is not thicker than 1-1/2” on the inside of the fireplace opening.
MQRB4436 / MQRB5143 / MQRB6961 Surround Installation Surround Kits are available in 3 different finishes: MQRB4436 MQRB5143 Small [1-1/2”] MQRB4419SBL MQRB4419SSS MQRB4419SPW Large [4”] MQRB4424SBL MQRB4424SSS MQRB4424SPW Small [1-1/2”] MQRB5019SBL MQRB5019SSS MQRB5019SPW Large [4”] MQRB5624SBL MQRB5624SSS MQRB5624SPW MQRB6961 Small [1-1/2”] MQRB6919SBL MQRB6919SSS MQRB6919SPW Large [4”] MQRB6924SBL MQRB6924SSS MQRB6924SPW -Black -Stainless Steel -Pewter Each kit contains: (Qty-1) Surround Frame (Qty
Fan Installation MQRB4436 / MQRB5143 / MQRB6961 SINGLE SIDED INSTALLATIONS: Fan Kit should be installed before the fireplace is placed into wall cavity. To remove fan for service, the burner pan must be removed and work done through the opening (See Burner System Removal section). WARNING Electrical Grounding Instructions This appliance is equipped with a three prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below. WARNING A qualified electrician must connect electrical wiring to junction outlet for built-in installation. Follow all codes.
MQRB4436 / MQRB5143 / MQRB6961 -Optional Glass Ember Installation If you wish to use this media evenly spread the glass embers onto the false bottom and burner. Ensure the glass embers do not excessively overlap as this will affect the flame pattern. Part Number MQG5W MQG5A MQG5C Description Decorative Ember Glass - White - 5 lbs Decorative Ember Glass – Azuria Blue - 5 lbs Decorative Ember Glass - Copper - 5 lbs MQRB4436 / MQRB5143: (MQG5W) 5 lbs of ½” White Ember Glass is supplied with every unit.
Optional Driftwood & Rock Installation The following Driftwood and Decorative Rock kits are available for the Infinite Series.
Door and Glass Information Glass Cleaning It will be necessary to clean the glass periodically. During startup, condensation, which is normal, forms on the inside of the glass, and causes dust, lint etc. to cling to the glass surface. Also, initial paint curing can deposit a slight film on the glass. It is therefore recommended that initially the glass be cleaned two or three times with a commercial fireplace glass cleaner.
Infinite Series Door Latch Tool MQRB4436 / MQRB5143 / MQRB6961 A Door Latch Tool is provided to assist with removing and installing the glass doors on the Infinite Series. While it is not necessary to use this tool, it may prove helpful. Wait until unit is Completely cool before touching glass or attempting to remove door. - Fireplace Parts Are Removed for Clarity Only - Step 1: Reach up into fireplace. Step 2: Grasp Latch with Tool. Step 4: Draw Latch forward with other hand.
Valve Access Cover Removal Remove Valve Access Cover in order to access igniter and valve controls. To remove Valve Access Cover, simply insert fingers into holes in Access Panel and lift out. When replacing Access Panel, engage Tabs into Slots in Bracket. MQRB4436 / MQRB5143 / MQRB6961 Removable Lower Face Panel Installers Note: The Lower Face Panel on the valve side of the unit is shipped attached with only 3 screws for easy removal.
Gas Line Installation This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CAN/CSA - B149.1 or .2 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas Code ANSI Z223 in the U.S.A. 1. The gas pipeline can be brought in through either the left side or the bottom of the appliance. A knockout is provided at either location to allow for the gas pipe installation and testing of any gas connection. 2.
Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A B BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When • Immediately call your gas supplier from a neighbour’s phone. Follow the lighting the pilot, follow these instructions exactly. gas supplier’s instructions.
Troubleshooting the Gas Control System WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Spark igniter will not light. Possible Causes Corrective Action Defective or misaligned electrode at pilot. Check for spark at electrode and pilot: if no spark and electrode wire is properly connected, replace igniter. Defective igniter (pushbutton). Using a match, light pilot.
Burner System Maintenance- MQRB4436 / MQRB5143 / MQRB6961 It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTIONBefore servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance. Allow the appliance to cool to room temperature.
Gas Conversion for Top Convertible Pilot (Series 019065X) – PART B Instructions for converting SIT 190 series pilot burner injection from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer’s Instructions. WARNING: The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer. 1. Shut off the gas supply to the appliance. 2. Allow the pilot burner to cool to room temperature.
Gas Conversion for Modulator – PART C -WARNING!- -WARNING!- 59
MQRB4436 Burner Section: Gas Conversion Models: MQRB4436N, MQRB4436LP, MQRB4436NE, MQRB4436LPE. Description Pilot Orifice Burner Orifice Kit Number Brass (1000-255) 4436MQ-CKLP LP Conversion 1001-P167SI #49 #30 (977.167) -Millivolt4436MQ-CKNG NG Conversion 1001-P165SI #33 #51 (977.165) -Millivolt4436MQ-CKLPI LP Conversion 1001-P168SI #49 #35 (977.168) -IPI4436MQ-CKNGI NG Conversion 1001-P166SI #33 #62 (977.
MQRB5143 Burner Section: Gas Conversion Models: MQRB5143N, MQRB5143LP, MQRB5143NE, MQRB5143LPE. Description Pilot Orifice Burner Orifice Kit Number Brass (1000-255) 5143MQ-CKLP LP Conversion 1001-P167SI #46 #30 (977.167) -Millivolt5143MQ-CKNG NG Conversion 1001-P165SI #30 #51 (977.165) -Millivolt5143MQ-CKLPI LP Conversion 1001-P168SI #46 #35 (977.168) -IPI5143MQ-CKNGI NG Conversion 1001-P166SI #30 #62 (977.
MQRB4436 / MQRB5143 Burner Tube Removal 1. 2. 3. Remove the six [6] DT screws from the lower portion of the Burner Tube Mount Brackets. Slide the Burner Tube away from the Plumbing Connection until it disengages from the orifice. Reverse these steps to reinstall. MQRB4436 / MQRB5143 Burner System Removal/Installation Guide -WarningTurn off Unit and allow to cool before cleaning. Only a Qualified service technician should service and repair this appliance. 1. 2. 3. 4. 5. Lift off Valve Access Cover.
MQRB4436 / 5143 / 6961 Moving Valve to Other Side of Fireplace Warning: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. The Valve Assembly may be changed to the other side of the fireplace. This must be done Before the unit is inside the enclosure. 1. Remove the Burner Tube (See Burner Tube Removal section in this Manual). Fig.1 2.
MQRB6961 Burner Section: Gas Conversion Models: MQRB6961N, MQRB6961LP, MQRB6961NE, MQRB6961LPE. Description Pilot Orifice Burner Orifice Kit Number Brass (1000-255) 6961MQ-CKLP LP Conversion 1001-P167SI #49 x 2 #30 (977.167) -Millivolt6961MQ-CKNG NG Conversion 1001-P165SI #34 x 2 #51 (977.165) -Millivolt6961MQ-CKLPI LP Conversion 1001-P168SI #49 x 2 #35 (977.168) -IPI6961MQ-CKNGI NG Conversion 1001-P166SI #34 x 2 #62 (977.
MQRB6961 Burner Tube Removal Air Shutter 1. Remove the six [8] DT screws from the lower portion of the Burner Tube Mount Brackets. 2. Slide the Burner Tube away from the Plumbing Connection until it disengages from the orifices. 3. Reverse these steps to reinstall. MQRB6961- Installer’s Note: If flames appear higher or lower at one end of the unit, the primary air can be adjusted on one of the two mixing sleeves to even the flame.
Remote Receiver Location For GT Series Remotes Only The Remote Receiver may be located inside of the unit- several inches to the left of the valve and near the front of the appliance. The Remote Receiver MUST be covered by the DCHS (Remote Control Heat Shield- see Parts List in manual). For All IPI Installations & GT Series Remotes Only The Remote Receiver may be located outside of the unit- up to a maximum of 6 feet from either side of the fireplace. An Extension Harness (Part No.
51-UHS For Infinite Series MQRB4436, MQRB5143, MQRB6961 The 51-UHS is designed for millivolt and IPI Infinite units for in-unit installation of the Remote Receiver, Fan Control Module, and the IPI Module. NOTE: When using GTF Fan Module, the 51UHS must be used. Remote Receiver IPI Module Fan Control Module BATTERIES Batteries for Remote Receiver can be changed by lifting 51-UHS 51-UHS can be inserted & removed from beneath up through opening.
IPI Electronic Ignition System Overview The IPI system is an advanced burner controller that provides you with the option of having either a Standing-Pilot, or an intermittent igniting system. This alternating mode is controlled by the CPI/IPI Switch (Continuous Pilot Ignition/Intermittent Pilot Ignition) located on the IPI System Box.
NOTE: The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft away installed in a certified deep wall switch electrical box (2-3/4” depth). For this configuration an extension wiring harness (P/N: 1001-P904SI) is required. Electrical Supply in Series: The entire IPI system can be powered by a single power source (i.e. by the AC Adapter). This is advantageous if you do not want to supply extra batteries.
Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A. This fireplace is equipped with an ignition device which automatically lights the pilot. Do NOT try to light by hand. B.
IPI Electronic Ignition Parts List – Standard System Item No. 1 Part No.
Caution: Electrical installation to be done by a qualified installer. All wires must be connected and grounded in accordance with CSA Standard C22.1- Canadian Electrical Code part 1 or with the National Electrical Code, ANSI /NFPA 70 (latest edition) and /or in accordance with local codes. Note: A 120 Volt electrical supply must be wired to a junction box on the side of the fireplace. EGTRC – Remote Control Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.
Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
IPI Photos (MQRB5143 Shown) Bottom of Unit with IPI Module Light Module &IPI Valve 74
Close up View of IPI Module Inside of IPI Module 75
IPI Valve IPI Valve 76
Millivolt Valve & Light Module Millivolt Valve 77
LK2 Halogen Lamp Kit MQRB4436 / MQRB5143 Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. SYSTEM NOTES 1. Each lamp is running on a dedicated circuit (Parallel circuit). This means that if one bulb fails the other will remain operational. 2. Switch circuit is on low voltage side of transformer. 3. Solid-state transformer is designed to run halogen lamps ONLY. 4.
LK3 Halogen Lamp Kit (MQRB6961) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. SYSTEM NOTES 1. Each lamp is running on a dedicated circuit (Parallel circuit). This means that if one bulb fails the rest will remain operational. 2. Switch circuit is on low voltage side of transformer. 3. Solid-state transformer is designed to run halogen lamps ONLY. 4.
Venting A. B. C. D. E. F. G. H. I. Clearance above grade, veranda, porch, deck, or balcony 12in [30cm] min.[1,2] Clearance to window or door that may be opened. 12in [30cm] min. for appliances 100,000BTUh [30kW] and lower, in Canada. [2] 9in [23cm] for appliances 50,000 BTUh and lower, in USA. [2] Clearance to permanently closed window min. 12in [30cm] recommended to prevent condensation on window, in Canada. 9in [23cm] for appliances 50,000 BTUh and lower, in USA.
General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (ZFlex) venting kits and components specifically approved and LABELED for this stove may be used. Kingsman Flex venting MUST be used on the MQRB4436 and MQRB6961. Use of Simpson Duravent or other hard pipe Venting systems is not permitted.
Figure 1 - Flex pipe spring spacing guide. Horizontal runs require support metal straps every 2ft. In an offset installation support straps should be used to stabilize pipe. Expand inner and outer flex pipe to the point that the outer flex pipe protrudes approximately 2 to 3 inches past outer wall and the inner flex protrudes approximately 2 to 3 inches past the outer flex pipe. Attach the inner flex pipe to the termination first and secure with sealant and [4] screws.
Minimum clearance to combustibles on venting is 1” with the following exceptions: MQRB4436 MQRB5143 MQRB6961 2” 2” 2” 5” with Z57WTS 5” with Z57WTS N/A Top of 90 degree elbow in an enclosure over 72” 4” 4” N/A Top of 90 degree elbow in an enclosure under 78” N/A N/A 6-1/2” with Z57WTS Top of 90 degree elbow in an enclosure over 78” N/A N/A 6-1/2” 60” 60” 64” Vertical 68” Horizontal 37-1/2” + ¼” rise/ ft 51-1/2” + ¼” rise/ ft 56-1/2” + ¼” rise / ft Top of horizontal Top of 90 degr
MQRB5143 Venting Examples All horizontal runs have a minimum ¼” rise per foot. 52-1/4" Wall Thimble and Roof Support The Wall Thimble is used in horizontal installations to shield the combustible material from the vent pipe. The appropriate size of thimble is required for each model. Please contact your local dealer for more information. Refer to Side Wall Venting for wall cutout information. The Roof Support is used to secure the vertical venting as it penetrates the roof.
Installation of Side Wall Venting Note: Wall Thimble Shield [Z57WTS] must be used in Enclosures under 72” for MQRB4436 / MQRB5143, and under 78” for MQRB6961. 3ft 5” Min. for MQRB4436 / MQRB5143 6-1/2” Min. for 52-1/4”Min Vertical rise over 3ft horizontal run (MQRB5143 shown). Note that the minimum height from the bottom of fireplace to the centre of vent is 37-1/2" [95 cm] for the MQRB4436, 51-1/2" [131 cm] for the MQRB5143 and 56-1/2” [144cm] for the MQRB6961.
Z57ST24 / Z57ST36 Horizontal Snorkel Terminations MQRB4436 / MQRB5143 -FOR INFINITE SERIES II MODELS ONLYTwo snorkel terminations are available for MQRB4436 / MQRB5143 If a vertical rise is necessary on the exterior side of a building: Z57ST24 (24” Tall, 14-1/2” Center to Center) Z57ST36 (36” Tall, 26-1/2” Center to Center) Follow standard horizontal venting installation procedures.
Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney (see Figure 5a). When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1" spiral nails.
Flue Restrictor Adjustment MQRB4436 / MQRB5143 Only –All Models The Flue Restrictor is located in the top of the Firebox in front of the Flue Opening. For vertically vented installations it is necessary to use the Flue Restrictor. Restrictor is set fully open from factory for short horizontal and vertical runs. To adjust the Flue Restrictor: Fig.1 1. Remove the [2] DT screws in the Flue Restrictor. Also remove the [2] screws at the front of the Flue (Fig.1). 2. Rotate the Flue Restrictor 180°. (Fig.2).
2” Top of Horizontal Vent Figure 4 - Clearances in horizontal venting. 43ft Figure 5 - a) Straight-through roof support configuration; b) Flex bend configuration; c) Termination mounting.
PVH58 INSTALLATION OVERVIEW The PVH58 Horizontal Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Either Hard Pipe or Flex Pipe can be used, along with the appropriate adapter kit. The Following Steps Are Required To Install The PVH58 Horizontal Power Vent: Install fireplace as per manual instructions (51MQ-MAN, 51MQ-MAN-II). Choose suitable location for PVH58 Power Vent Termination.
PVH58 VENTING CLEARANCES Note: Clearances are to the edge of terminal plate, add 5-1/2" to clearances to arrive at center line. Note: Local Codes or Regulations may require different clearances. A. Clearance above a veranda, porch, deck, or balcony or other combustible surface is 27”. Clearance above grade is12in [30cm] min.[1,2]. B. Clearance to window or door that may be opened. 12in [30cm] min. for appliances 100,000BTUh [30kW] and lower, in Canada.
PVH58 VENTING HARD PIPE OR FLEX The PVH-58 Power Vent is approved for the following models only: MQRB4436, MQRB5143, MQRB6961 Refer to fireplace manual (51MQ-MAN or 51MQ-MAN-II) for proper installation of your fireplace. Approved For 5/8” Hard Pipe The PVH-58 Power Vent is approved for use with Simpson Dura-vent Direct Vent system (Model DV-GS Series), and AmeriVent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
PVH58 Venting Adapters ADAPTERS REQUIRED FOR HARD PIPE INSTALLATION Adapters Required At Fireplace MQRB4436, MQRB5143 Z57DFA MQRB6961 Z69DFA ADAPTERS REQUIRED FOR FLEX PIPE INSTALLATION Adapters Required At Power Vent* * One 12” section of hard pipe must be connected directly to the Power Vent before any adapters are connected.
PVH58 VENTING CONFIGURATIONS Refer to Air Intake Adjustment section of this manual to adjust Air Intake Shutter. PVH-58 Maximum / Minimum Vent Lengths: Maximum Vent Length is 125 ft plus six 90° elbows with Air Intake Shutter fully closed. Termination must not be below unit. This power vent can be installed up to 3ft below the installed fireplace on runs less than 100ft and not more than four 90° elbows. Minimum Vent Length is 3ft plus one 90° elbow with Air Intake Shutter fully open.
PVH58 WALL THIMBLE INSTALLATION An 11 inch square opening is required. Center Wall Thimble over the 11 inch square opening and secure both pieces on either sides of the wall. Ensure that cutout is at the lower right corner, as electrical conduit must pass through this area. Cutout At Lower Right Corner when looking into building. Telescopic Wall Thimble PVH58 POWER VENT MOUNTING Route wiring harness through wall thimble. Mount Power Vent unit onto building.
PVH58 WARNING A qualified electrician must connect electrical wiring to junction outlet for built-in installation. Follow all codes. Wiring Harness Connections WARNING Electrical Grounding Instructions – This appliance is equipped with a three – pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. WARNING Label all wires prior to disconnection when servicing controls.
PVH58 Millivolt System Connections 10ft Double Pole Switch Wiring Harness for Millivolt Systems. Connects to Double Pole Switch as Shown. A 20ft extension harness can be ordered. See Wiring Harness Connections section for installation of extension harness. GREEN/GRND BROWN RED BLACK WHITE Route Switch Wiring Harness through second ¾” opening in fireplace as shown. DOUBLE POLE SWITCH POWER VENT Power Vent Control Module Mount Power Vent Control Module in fireplace.
Connect to TH and TH / TP Tabs on Valve Connect to Power Vent Cable Connect to Double Pole Switch Cable Plug into120v AC Outlet DOUBLE POLE SWITCH (SUPPLIED) MILLIVOLT POWER VENT CONTROL MODULE FIREPLACE IS SUPPLIED WITH ONE JUNCTION BOX. ADDITIONAL OUTLETS MAY BE REQUIRED. CONSULT A QUALIFIED ELECTRICIAN. NOTE: Double Pole Switch can be replaced with 120V Double Pole Thermostat. Contact an Electrician for installation. *In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.
PVCM Schematic - Millivolt 99
PVH58 IPI SYSTEM CONNECTIONS Mount Power Vent Control Module In Fireplace. Lamp Transformer housing may need to be moved toward valve. Reposition Lamp Transformer housing. Install Power Vent Control Module as shown. POWER VENT CONTROL MODULE Power Vent Control Module Mounted inside fireplace (TOP VIEW). WIRING HARNESS IPI SYSTEM Connect Wiring Cold Climate Switch Must Be Disconnected From IPI Wiring Harness. Remove Batteries From Battery Backup.
IPI VALVE ORANGE - NORMALLY CONNECTS TO VALVE AT PV1-A POSITION PLUG PV3-A INTO GREEN WIRE ON 912 OR GREEN TH WIRE ON 905 HARNESS 584.912 HARNESS & IPI MODULE -CONNECT ON/OFF DEVICESWITCH, GREEN TH WIRE FROM #905 HARNESS FOR REMOTE CONTROL, ETC FIREPLACE IS SUPPLIED WITH ONE JUNCTION BOX. ADDITIONAL OUTLETS MAY BE REQUIRED. CONSULT A QUALIFIED ELECTRICIAN. *In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative).
PVCM Schematic - IPI 102
PVH58 Air Intake Adjustment The PVH58 is shipped with the air intake adjustment fully closed. This will produce maximum draw at the fireplace. Longer runs require more draw, while shorter runs require less. If flame pattern is slow and lazy, and sooting is occurring, more draw is required. If flame pattern is running too fast, less draw is required. Flame pattern should appear similar to below: -AIR INTAKE ADJUSTMENTIf air intake adjustment is required, loosen screw at bottom of Power Vent as shown.
PVH58 Troubleshooting NOTE: Before connecting Power Vent Control Module, ensure that all other systems and accessories (Remote Control, Fan, Lights, etc.) are connected and working properly. !WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. BEFORE TROUBLESHOOTING THE GAS CONTROL SYSTEM, BE SURE EXTERNAL GAS SHUT OFF IS IN THE "ON" POSITION. !WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MQRB4436 AND MQRB5143 VENTING AND VENTING ADAPTERS For fireplaces to be converted to hard pipe (Simpson Duravent, etc.
58PVH-P3211 3/4” K.O.
MQRB4436 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -44” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Burner, Two Sides Open, SIT Valve with Hi/Lo Flame and BTU Adjustment, Ceramic Glass, 5/7" Flue, Wall Switches, Junction Box, Accent Lighting with Decorative Ember Glass, 33,000 BTU MQRB4436N Linear Multi-Sided Fireplace, Millivolt Valve (as above) Natural Gas MQRB4436LP Linear Multi-Sided Fireplace, Millivolt Valve (as above) Liquid Propane MQRB4436NE Line
4436MQ-BLPSIE Burner Assembly- Liquid Propane c/w Valve System (MQRB4436LPE) 4436MQ-BNGSIE Burner Assembly-Natural Gas c/w Valve System (MQRB4436NE) Conversion Kit 4436MQ-CKLP LP Conversion Kit for MQRB4436 Millivolt 4436MQ-CKNG NG Conversion Kit for MQRB4436 Millivolt 4436MQ-CKLPI LP Conversion Kit for IPI MQRB4436LPE IPI 4436MQ-CKNGI NG Conversion Kit for IPI MQRB4436NE IPI Venting Accessories Z57HSK5 Horizontal Round Termination Vent Starter Kit - 5/7" X 5 FT Length, Wall Thimble Shield,
MQRB5143 -Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -51” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Burner, Two Sides Open, SIT Valve with Hi/Lo Flame and BTU Adjustment, Ceramic Glass, 5/7" Flue, Wall Switches, Junction Box, Accent Lighting with Decorative Ember Glass, 40,000 BTU MQRB5143N Linear Multi-Sided Fireplace, Milli Volt Valve (as above) Natural Gas MQRB5143LP Linear Multi-Sided Fireplace, Milli Volt Valve (as above) Liquid Propane MQRB5143NE Li
5143MQ-BNGSI Burner Assembly-Natural Gas c/w Valve System (MQRB5143N) 5143MQ-BLPSIE Burner Assembly- Liquid Propane c/w Valve System (MQRB5143LPE) 5143MQ-BNGSIE Burner Assembly-Natural Gas c/w Valve System (MQRB5143NE) Conversion Kit 5143MQ-CKLP LP Conversion Kit for MQRB5143 Millivolt 5143MQ-CKNG NG Conversion Kit for MQRB5143 Millivolt 5143MQ-CKLPI LP Conversion Kit for IPI MQRB5143LPE IPI 5143MQ-CKNGI NG Conversion Kit for IPI MQRB5143NE IPI Venting Accessories Z57HSK5 Horizontal Round
MQRB6961-Parts List Marquis Infinite Zero Clearance Direct Vent Gas Fireplace -69” Wide Listed for USA/Canada as a Decorative Appliance: Linear LH Burner, Two Sides Open, SIT Valve with Hi/Lo Flame and BTU Adjustment, Ceramic Glass, 7/10" Flue, Wall Switches, Junction Box, Accent Lighting with Decorative Ember Glass, 62,000 BTU MQRB6961N Linear Multi-Sided Fireplace, Milli Volt Valve (as above) Natural Gas MQRB6961LP Linear Multi-Sided Fireplace, Milli Volt Valve (as above) Liquid Propane MQRB6961NE Li
6961MQ-BLPSI Burner Assembly- Liquid Propane c/w Valve System (MQRB6961LP) 6961MQ-BNGSI Burner Assembly-Natural Gas c/w Valve System (MQRB6961N) 6961MQ-BLPSIE 6961MQ-BNGSIE Burner Assembly- Liquid Propane c/w Valve System (MQRB6961LPE) Burner Assembly-Natural Gas c/w Valve System (MQRB6961NE) Conversion Kit 6961MQ-CKLP LP Conversion Kit for MQRB6961 Millivolt 6961MQ-CKNG NG Conversion Kit for MQRB6961 Millivolt 6961MQ-CKLPI LP Conversion Kit for IPI MQRB6961LPE IPI 6961MQ-CKNGI NG Conversion
Common Parts for MQRB4436, MQRB5143 and MQRB6961 Accessories Z1MT Thermostat (Not permitted for vented gas fireplaces installed in the U.S.A.) Millivolt Wall Mount 3927ZDV-P779-1 Bulb 10W 12V 64418 or [Sylvania 58691] (Lightbulbs NOT covered under Warranty.) 5143-P77912 Lamp Assembly 58mm (Lightbulbs NOT covered under Warranty.
Valve System Parts 1000-P136WR Thermopile GOAI-524 1001-P069SI Electrode Sparker OFP42SA Spark Assist 1001-P216SI Thermocouple 290.216TC SIT 1001-P165SI Orifice Pilot NG977.165TC SIT 1001-P167SI Orifice Pilot LP977.167TC SIT 1001-P633SI Valve Nova LP Hi/Lo 0820651 1001-P634SI Valve Nova NG Hi/Lo 0820652 1001-P713SI Pilot Burner LP 199.713TC SIT 1001-P714SI Pilot Burner NG 199.
This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation and only if the unit is installed inside the continental United States, Alaska, Hawaii, and Canada. The warranty applies only if the unit is installed and operated in accordance with the printed instructions and in compliance with applicable installation and building codes and good trade practices.