9 BEEP CODE SEQUENCES
In the following table, and .a period ( . ) represents a short beep a dash (-) represents a long beep
NOTE: This option is available only if sound is enabled.
Sequence Description
- Card read error. Place the card again or use a different card.
. -
Terminal validation failed. Server reports that the terminal is not registered on SafeQ.
- - No print job is waiting in queue.
. . -
User quota has been exceeded or user has no billing code assigned.
- . -
User authentication failed. The PIN is not valid or the ID card is not registered in SafeQ. If
YSoft Payment System is used, it can indicate account is disabled.
. - -
The terminal received an error or warning message from the SafeQ server.
If YSoft Payment System is used, it can indicate insufficient credit balance for current user
(according SafeQ system settings for YSoft Payment System -
) to perform copies/scans.
pricePerPageReservationStrategyForCopyOnHwTerminal
- - - Connection to SafeQ server failed.
. . . -
Hardware configuration is corrupt and the terminal cannot continue booting.
- .. -
Maximum number of firmware update attempts reached but no valid firmware detected.
. - . -
Firmware update failed.
- - . -
Software configuration cannot be saved. Probably faulty terminal EEPROM.
. . - -
Software configuration is damaged and the terminal is loading defaults.
- . - -
Maximum number of firmware update attempts reached and the terminal is resuming normal
boot.
. - - -
Firmware damaged.
- - - -
Network initiation failed.
. . . .
Keyboard PCB failure.
- . . .
No reader is connected. Reader is required for operation.
. - . .
Firmware update failed. Error in server response. SafeQ server is probably not configured
correctly.
- - . .
Firmware update failed. Cannot connect to SafeQ server.