User Manual
21
MAINTENANCE NOTE FOR DIA100
Change of Cotton Filament (76-1411030):
Please note that the cotton filament cannot be washed with the water. Water drops
would be sucked into the Pump and may cause the pump damaged within 1 to 2
months. If you wash with the water, Cotton filament will turn solid and will stop the
DIA100 working well. Please change at least once 3 to 5 days if you use 8 hours per
day.
Change of Charcoal Filter (78-151500):
Charcoal filter will turn solid if you wash with the water. If you use 8 hours per day
that the Charcoal filter has to be changed within 3 weeks. On the other hand, if you
wash the Charcoal filter and do not dry properly, water drops will be sucked into the
Pump and may cause the pump damaged easily.
Change of Glass Solder Collector (75-160110):
Glass solder collector will be broken easily if the client knocked the DIA100 against
the desktop. The glass collector also needs to be changed every 3 to 5 months usage.
Maintenance for Desoldering Heater and Tip:
To prevent the desoldering tip being stuck by solder, the desoldering tip has to be
cleaned by a Probe after every time usage. In such ways, desoldering tip’s life can be
lasting longer. Desolder Heater would be probably broken when you remove the
desoldering tip with a pliers careless in hot condition. Slightly remove the tip with
pliers or may use the anti-rusty cleaner when the tip clogged with the heater and do
not forced open. Please read the “Procedure for Cleaning Clogged Tips” carefully
on page18 on the manual.
PROCEDURE FOR REPLACING HOT AIR GUN HEATING
ELEMENT
1.Unscrew the 3 screws on handle then take out the handle cover.(See Fig.1 below)
2.Disconnect the grounding wire jack and pull the heating element out from the
stainless steel tube.
Caution :The main swich must be “off” and allow the iron to cool
before attemptling the following procedure