Instruction Manual
Installation, Operating and Maintenance Instruction
Model MP, MPA, MPAI
MP 100-english page 81
Revision 04
Article No 771074011
Issue 11/2011
pic 4 - Alignment of coupling with gauge and ruler
pic 5 - Adjustment using dial gauge
Control alignment of coupling again in operation
warm condition and on system
pressure (if
available) and correct, if necessary. Pay
atten
tion to chapter 6 beforehand! It must be
possi
ble to turn the unit easily and harmoniously
by hand.
Improper alignment of the unit can lead to
damages at coupling and unit!
Mount coup
ling guard after alignment and
before start-up.
5.3.3 Permitted displacement for flexible couplings
Coupling size
H80FK
H95FK
H110FK
B125KF
H125FK
B140FK
H140FK
B160FK
H160FK
B180FK
H180FK
B200FK
H200FK
B2
25
FK
H2
25
FK
Outer diameter of coupling
[mm]
80
95
110 125
140
160
180
200
225
Axial distance S
S
max
3 6
S
min
2
Max. radial displacement
∆K
r
0,1 0,2
Max. angular
displacement
S
max
. S
min
∆K
w
= S
max
- S
min
0,1 0,2 0,3
The given values
∆
K
r
and
∆
K
w
apply for 1500 min
-1
.
For all other speeds the following applies:
∆
K
w
. S
n
bzw.
∆
K
r
. S
n
5.3.4 Coupling Guard
Acc. to accident prevention regulations the
pump must only be operated with coupling
guard.
Care has to be taken, that the used coupling
guard consists of non-sparking material.
Parts:
Assembly:
ruler
gauge
ruler
speed n [min
-
1
]
speed
factor S
n