ONLINE VALUES: I/O NO.: VALUE: DESCRIPTION:
Digital output 1 0 read/write Digital outputs are READ and WRITE signals
Digital output 2 1 read/write
Digital output 3 2 read/write
Digital output 4 3 read/write
Digital output 5 4 read/write
Digital output 6 5 read/write
Digital output 7 6 read/write
Digital output 8 7 read/write
Digital input 1 10 read Digital inputs are READ ONLY signals.
Digital input 2 11 read
Digital input 3 12 read
Digital input 4 13 read
Digital input 5 14 read
Digital input 6 15 read
Digital input 7 16 read
Digital input 8 17 read
Digital input 9 20 read
Digital input 10 21 read
Digital input 11 22 read
Digital input 12 23 read
Digital input 13 24 read
Digital input 14 25 read
Digital input 15 26 read
Digital input 16 27 read
Alarm input 1 30 read/reset Alarms are READ and RESET signals.
Alarm input 2 31 read/reset
Alarm input 3 32 read/reset
Alarm input 4 33 read/reset
Alarm input 5 34 read/reset
Alarm input 6 35 read/reset
Alarm input 7 36 read/reset
Alarm input 8 37 read/reset
Alarm input 9 40 read/reset
Alarm input 10 41 read/reset
Alarm input 11 42 read/reset
Alarm input 12 43 read/reset
Alarm input 13 44 read/reset
Alarm input 14 45 read/reset
Alarm input 15 46 read/reset
Alarm input 16 47 read/reset
Limit relay (high)1 50 read The condition of the limit relays can be read.
Limit relay (high)2 51 read
Limit relay (high)3 52 read
Limit relay (high)4 53 read
Limit relay (low)1 54 read
Limit relay (low)2 55 read
Limit relay (low)3 56 read
Limit relay (low)4 57 read
Limit relay (high)1 60 read/reset Alarms can be set and reset (cancelled).
Limit relay (high)2 61 read/reset (0-255)
Limit relay (high)3 62 read/reset
Limit relay (high)4 63 read/reset
Limit relay (low)1 64 read/reset
Limit relay (low)2 65 read/reset
Limit relay (low)3 66 read/reset
Limit relay (low)4 67 read/reset
704 output 1 70 read/write An output (pump) can be activated if the level is higher
704 output 2 71 read/write than the stop level, or an output can be deactivated
704 output 3 72 read/write if the level is lower than the start level.
704 output 4 73 read/write
704 alarm 1 74 read/reset Read or reset alarm
704 alarm 2 75 read/reset Læs eller afstil alarm
704 alarm 3 76 read/reset Læs eller afstil alarm
704 alarm 4 77 read/reset Reset
100 read/write
101 read/write
Communication flag 102 read/write Bit 102 is set by the 795 on alarm transmission ans must be reset
by the main station when the alarm has been received.
Power failure 103 read/reset Reset
704 system error 104 read/reset Reset
105 read/write
704 Flow calculation possible 106 read/write
Alarm bit for test alarm 107 read/reset Test alarm bit is set and reset on I/O107
110 read/write
111 read/write
112 read/write
113 read/write
114 read/write
115 read/write 704 Interlock status bit ( Read / Write bit)