Instruction Manual

Page 8
PrPr
PrPr
Pr
essuressur
essuressur
essur
e transmittere transmitter
e transmittere transmitter
e transmitter
7050 / 70607050 / 7060
7050 / 70607050 / 7060
7050 / 7060
Bracket
Min. 65mm
inside
MountingMounting
MountingMounting
Mounting
The Pressure Trans-
mitter is hung inside
the well or container
where measurement is
desired. It is practical
to mount it in a tube,
fastening it at the top
end of the tube by
means of the fittings
supplied as this
facilitates subsequent
cleaning and
inspection.
SpecificationsSpecifications
SpecificationsSpecifications
Specifications
Pressure Transmitter 7050 or 7060Pressure Transmitter 7050 or 7060
Pressure Transmitter 7050 or 7060Pressure Transmitter 7050 or 7060
Pressure Transmitter 7050 or 7060
Measuring ranges:
0-10m Pressure Transmitter 7050-1413,(absolute press.)
0-3m Pressure Transmitter 7060-1413,(gauge pressure)
0-10m Pressure Transmitter 7060-1423,(gauge pressure)
0-30m Pressure Transmitter 7060-1433, (gauge pressure)
Function: 2-wire, 4-20 mA
Accuracy: ±1%
Temperature: –10 - +60
O
C
Dimensions: ø60 x 140 mm
Materials: House: PP
Diaphragm: Acidproof steel, AISI 316 L
Cable: 2 x 0,5mm², length=12m
(with 7060-1433: 35m), can be extended
Mounting: Immersed from supplied bracket
Housing: IP 68, waterproof, max. 3 bar
Zero, span and response timeZero, span and response time
Zero, span and response timeZero, span and response time
Zero, span and response time
The response time is set to minimum at delivery. When
replacing the Pressure Transmitter or when using the MJK
703P for differential level measurement or measurements in
pressure or vacuum tanks, it may be necessary to set the
zero point as well as the span. The setting is carried out by
simulating the zero point and the span. Depending on the
use, it may also be necessary to reset the response time.
If the Pump Controller is used for liquids with a specific
gravity different from that of water (e.g. sludge), the span
will need to be adjusted.