Owner's manual
© 2013 Flowtronex
54
Omron Touch-Screen Display
!
!
!
!
!
!
!
·
N80:31 is the delay time until Fill starts. This is normally set to 10 seconds.
!
·
N80:32 is the delay time until Fill stops. This is also normally set to 10 seconds.
!
One other function is defined on this screen—Flow Activated PLC Relays. Depending on the
equipment connected to the relay, such as a fertigation relay, these two outputs can be used to set up
a minimum station flow required for operation.
!
·
N84:0 is the Flow Activated PLC Relay 1. The default is 100 GPM.
!
·
N84:1 is the another Flow Activated PLC Relay 1 that is rarely used. The default is 0 GPM.
!
·
Tap the value field next to any of these registers and the calculator/keypad pops-over the screen.
Enter or edit the value. (See also, Calculator/Keypad.)
!
·
Optionally, press the Main Menu touch key to return to the Main Menu. (See also, Main Menu.)
!
·
Optionally, press Back to return to the Register Access screen.
!
·
Press the up
(
▲
)
or down arrow
(
▼
)
key to display other Accessories parameters screens.
!
2.11 Define My Filter Parameters
!
You can access the Accessories screen and define your Filter parameters by pressing the Register
Access touch key on the Main Menu and opening the Register Access screen.