Owner manual
Pump station with SSH pumps
Example product code
V 2 HE F 4 P A L 2 BCD
Numbering system definitions
First character: Variable or constant speed
V = variable speed C = constant speed
Second character: Number of pumps
2, 3, or 4
Third character: Pump type and size
H9 = 9SH HA = 10SH HB = 11SH H4 = 4SH
H7 = 7SH H5 = 5SH H8 = 8SH H6 = 6SH
HC = 24SH HD = 25SH HE = 22SH HF = 27SH
HG = 23SH HH = 28SH — —
Fourth character: Header size
C = 3 in. E = 6 in. G = 10 in.
D = 4 in. F = 8 in. H = 12 in.
Fifth character: Supply voltage
2 = 208 V / 1 PH / 60 Hz 6 = 460 V / 3 PH / 60 Hz
3 = 230 V / 1 PH / 60 Hz 7 = 575 V / 3 PH / 60 Hz
4 = 208 V / 3 PH / 60 Hz 8 = 380 V / 3 PH / 60 Hz
5 = 230 V / 3 PH / 60 Hz 9 = 380 V / 3 PH / 50 Hz
Sixth character: HP rating
A = 1/2 E = 2 J = 10 N = 30 T = 75
B = 3/4 F = 3 K = 15 P = 40 U = 100
C = 1 G = 5 L = 20 R = 50 V = 125
D = 1-1/2 H = 7-1/2 M = 25 S = 50 W = 150
Seventh character: Trim
9SH 10SH 11SH 4SH 7SH 5SH 8SH 6SH 22SH 23SH 24SH 25SH 27SH 28SH
A 6-5/8 8-27/6
4
10-3/3
2
6-3/4 8-1/4 6-7/8 8-1/4 7-5/16 9-1/16 9-1/16 9-7/8 9-7/8 10-3/8 10-5/8
B 6-7/16 8-1/16 9-17/3
2
6-3/8 7-13/16 6-7/16 7-3/4 7-1/8 8-3/4 8-11/1
6
9-1/2 9-1/2 9-15/1
6
10-1/4
C 5-11/16 7-11/1
6
9-1/8 6-1/16 7 5-13/1
6
7-1/2 6-15/1
6
8-1/2 8-6/16 9-3/16 9-1/8 9-9/16 9-13/16
D 5-3/8 7-3/8 8-3/4 5-5/8 6-3/4 5-1/2 7-3/16 6-11/1
6
8-1/4 8-1/16 8-7/8 8-13/16 9-1/4 9-7/16
E — 7-1/8 — 5-5/16 6-7/16 5-1/8 6-7/8 6-3/8 7-7/8 7-11/1
6
8-9/16 8-3/16 8-3/4 9-1/16
Technical Reference
TechnoForce Package System Mechanical Installation, Operation, and Maintenance Manual 29