Instructions / Assembly
REMOVING THE MANUAL AIR RELIEF VALVE
WARNING
This product should be installed and serviced only
Your Filter comes with a Manual Air Relief Valve (MAR)
preinstalled rom the factory.
to be serviced, follow these instructions carefully.
1. Turn off all system circulation pumps and all electric
power on the equipment pad.
2. Set all system valves in a position to prevent water
3. The manual air relief valve must be placed in the OPEN
position.
4. Wait until all water leakage has stopped.
5. The air relief valve can be removed by screwing the
whole parts counter clockwise.
RE-INSTALLATION OF THE MANUAL AIR RELIEF VALVE
1. Check the o-ring seals, replace as needed.
6. Verify the MAR discharge points away from all electrical connections.
WINTERIZING FILTER
WARNING
from damage.
2. Follow directions under FILTER DISASSEMBLY INSTRUCTIONS
3. Then follow REMOVING per instructions
4. Reassemble per FILTER RE-ASSEMBLY INSTRUCTIONS.
Figure 10