Use and Care Manual
IMPORTANT SAFETY INFORMATION
This lter operates under high pressure. When any part of the circulating system (e.g., clamp, pump, lter,
valves, etc.) is serviced, air can enter the system and become pressurized. Pressurized air can cause the
lid or control valve to separate which may result in serious injury, death, or property damage. To avoid this
potential hazard, follow these instructions.
1. Before repositioning valves and before beginning the assembly,
disassembly, or adjustment of the clamp or any other service of the circulating system:
(a) Turn the pump off and shut off any automatic controls to ensure the system is not inadvertently started
during the servicing;
(b) Open manual air relief valve;
(c) Wait until all pressure is relieved, pressure gauge must read zero (0).
2. Whenever installing the lter clamp, follow the lter valve and clamp installation instructions exactly.
3. Once service on the circulating system is complete, follow system restart instructions exactly.
4. Maintain circulation system properly. Replace worn or damaged parts immediately.
Failure to operate your lter system or inadequate ltration can cause poor water clarity obstructing
visibility in your pool and can allow diving into or on top of obscured objects, which can cause serious
personal injury or drowning.
This lter operates under pressure. With the valve clamped properly and operated without air in the
system, this lter will operate in a safe manner. Air entering the lter and the valve not clamped
correctly can cause the valve to separate, which could cause serious personal injury and/or property
damage.
Always turn pump off before changing valve positions. Changing valve positions while the pump is running
can damage the control valve, which may cause serious injury or property damage.
Chemical fumes and/or spills can cause serious corrosion to the lter and pump structural components.
Structurally weakened components can cause lter, pump or valve attachments to separate and could
cause serious bodily injury or property damage.
High voltage can cause serious or fatal injury. Always install a suitable GFCI at the power source of this
unit as an added safety precaution. Article 681-31 of the NEC requires that a GFCI be used if this pump
is used with a storable pool.
Never work on the pump while it is running or power is still connected. High voltage can cause
serious or fatal injury. A suitable ground fault interrupter should always be installed at the power supply
source of this unit. Be sure to ground the motor before connecting to electrical AC power supply. Failure
to ground the motor can cause serious or fatal electrical shock hazard. DO NOT ground to a gas supply
pipe line.
FOR CORD AND PLUG CONNECTED UNITS: Connect only to a ground type receptacle protected
by a Ground Fault Circuit Interrupter (GFCI). Contact a qualied electrician if you cannot verify that the
receptacle is protected by GFCI. Do Not Bury Cord. Locate cord to minimize abuse from lawn mowers,
hedge trimmers, and other equipment. To reduce the risk of electrical shock, replace damaged cord
immediately. To reduce the risk of electrical shock, Do Not Use an extension cord to connect unit to
electrical supply; provide a properly located outlet.
3