Use and Care Manual

INSTALLATION
POND SIZE / WITH OR WITHOUT FISH
The lter system with integrated UVC must be running permanently, 24 hours a day. The UVC lamp must be
replaced after 8,000 hours of operation in order to ensure that the lter UVC continues to operate properly.
The selection table allows for a maximum height difference of 1m between
the surface of the water and the highest point of the ltering system. If the
height difference is greater than 1m, you should use a corresponding pump
with more power. For hoses that are longer than 4m, always use hoses that
correspond to the upper value of the scale.
PRESSURE LOSS DUE TO HEIGHT DIFFERENCE
In order to avoid pressure loss, cut the spiral stepped hose adapter at the
relevant points for each hose. Avoid unnecessary corners and bends which
contribute to further pressure loss.
Choose a suitable location for the pressure lter. Install the lter so that it
is safe from ooding. Secure your lter so that it won’t fall into the pond. Be
sure to place it at least 2m from the edge of the pond.
INSTALLING AND CONNECTING THE PRESSURE FILTER
Place the lter on a rm, level base. The lter can also be dug in up to the
step on the lter box. Make sure there is unhindered access to the lid in
order to be able to carry out work on the lter.
Decide which hose diameter you need based on the selection table. Only
operate the lter with pressure hoses that are approved for a pressure of
0.2bar (the maximum pressure of the pump). It is recommended to warm
the hose with hot water, pushing it onto the spiral stepped hose adapter and
securing it with a hose clip. This makes the connection watertight. To avoid
pressure loss, cut the spiral stepped hose adapter at the relevant point to
t each hose.
CONNECTION AT THE WATER INLET
Push the union nut onto the black spiral stepped hose adapter. Push/twist the hose on and secure with a
hose clip. Insert the at seal into the union nut and screw tight onto the water inlet nozzle. We recommend
diverting the clean water via a small watercourse, for example, instead of feeding it directly back into the
pond. This enriches the water with additional oxygen. Connecting to a cleaning connection, you can have a
drainage hose permanently connected to the cleaning connection. This allows you to drain the dirty water
directly into the sewage system or onto a ower bed.
5